Metraipolis › archive › dc_dbc654478c5e

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling — arXiv:2609.03085

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.03085
License (as archived)
CC0-1.0
Archived
2026-10-17T02:56:09.306Z
SHA-256 of the archived text
2036db8db2ac8f4f3ae76e4c5b22aaadd90967f4bd484149140f4f8c9bcc907e
Stable URL of this page
https://metraipolis.com/documento/dc_dbc654478c5e

How to cite

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling — arXiv:2609.03085 — arXiv (en), https://arxiv.org/abs/2609.03085 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_dbc654478c5e (Metraipolis archive dc_dbc654478c5e, sha256 2036db8db2ac8f4f3ae76e4c5b22aaadd90967f4bd484149140f4f8c9bcc907e)
BibTeX
@misc{dcdbc654478c5e,
  title = {Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling — arXiv:2609.03085},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.03085},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_dbc654478c5e; sha256 2036db8db2ac8f4f3ae76e4c5b22aaadd90967f4bd484149140f4f8c9bcc907e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.03085. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

There is growing interest in adopting CLIP-style vision--language model (VLM) pretraining for mammography. However, models that directly employ the standard CLIP architecture and training objective exhibit limited zero-shot performance in clinically important tasks such as cancer, finding-type, and BI-RADS predictions. We argue that this underwhelming performance is due to neglecting two characteristics of mammography data: (1) its high-res nature, and (2) homogeneity of radiology reports, largely driven by a predominance of negative/benign findings on examinations. We propose TopKSigLIP, a VLM designed to address these two limitations through a novel architecture and learning objectives. Instead of downscaling high-res mammography images to satisfy GPU memory constraints, TopKSigLIP introduces TopK-Patch module that learns to sample a sparse set of high-res patches likely to contain lesions, sidestepping the resolution--batch size tradeoff of VLM training. The sampled patch locations additionally serve as a built-in localization tool. To address report homogeneity, we replace the contrastive loss, which falsely repels semantically similar pairs, with a Sup-sigmoid loss. Sup-sigmoid loss extends the sigmoid loss from SigLIP with soft labels derived from structured data. TopKSigLIP outperforms existing open-source mammography and general medical VLMs on both internal and external benchmarks on density assessment, BI-RADS classification, finding subtyping, and cancer prediction under zero-shot evaluation. TopKSigLIP remains competitive under linear probing despite using a significantly smaller vision encoder and smaller training batches than baselines. The TopK-Patch module additionally achieves superior lesion localization over post-hoc Grad-CAM. Code and weights are made public: this https URL .

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-04 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.03085 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T02:27:18.931Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-04?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).