Metraipolis › archive › dc_db868ef391a4

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation — arXiv:2609.25642

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.25642
License (as archived)
CC0-1.0
Archived
2026-10-08T16:43:29.975Z
SHA-256 of the archived text
eccb2abcc1549e52a1dd9ddf6e491fc273e1b5cd328dded550dc128572f34771
Stable URL of this page
https://metraipolis.com/documento/dc_db868ef391a4

How to cite

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation — arXiv:2609.25642 — arXiv (en), https://arxiv.org/abs/2609.25642 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_db868ef391a4 (Metraipolis archive dc_db868ef391a4, sha256 eccb2abcc1549e52a1dd9ddf6e491fc273e1b5cd328dded550dc128572f34771)
BibTeX
@misc{dcdb868ef391a4,
  title = {Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation — arXiv:2609.25642},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.25642},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_db868ef391a4; sha256 eccb2abcc1549e52a1dd9ddf6e491fc273e1b5cd328dded550dc128572f34771},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.25642. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motorised instruments through 6 mm trocars. The core contribution is the numerical and contact design that keeps this cell stable: implicit integration, simulation meshes separate from collision meshes, numerical guards, and a grasp constraint captured at the live tissue pose. In 45 repeated grasp-lifts, a friction grasp held the tissue in 0 of 15 trials and each constraint grasp in 13 of 15; on displaced tissue, a rest-pose constraint produced one-step snaps of up to 17.8 mm, which live-pose capture eliminates. Against the recording, front-surface depth error is 1.33 to 1.41 mm, organ silhouette IoU is 0.80, and in five grasp-lifts reproduced from video the landmark displacement RMSE is 11.8 mm against 14.2 mm for a static prediction. Biofidelity is not claimed; the environment is intended for closed-loop feasibility, safety, contact and policy screening.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-23 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.25642 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T15:56:53.446Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).