Metraipolis › archive › dc_db016ff51897
GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT — arXiv:2609.11312
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.11312
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T05:27:02.049Z
- SHA-256 of the archived text
b1c8da84d0d5eccf94d7157ca089e9fda632ffee6d5d55d7b5f0c13b41355f3e- Stable URL of this page
https://metraipolis.com/documento/dc_db016ff51897
How to cite
GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT — arXiv:2609.11312 — arXiv (en), https://arxiv.org/abs/2609.11312 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_db016ff51897 (Metraipolis archive dc_db016ff51897, sha256 b1c8da84d0d5eccf94d7157ca089e9fda632ffee6d5d55d7b5f0c13b41355f3e)
BibTeX
@misc{dcdb016ff51897,
title = {GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT — arXiv:2609.11312},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.11312},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_db016ff51897; sha256 b1c8da84d0d5eccf94d7157ca089e9fda632ffee6d5d55d7b5f0c13b41355f3e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.11312. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises [email protected] to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-11 in cs.AI). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2609.11312 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T05:17:52.147Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).