Metraipolis › archive › dc_d996d9f6db07

EMA-Based Subspace Tracking for Adaptive Artifact Subspace Reconstruction — arXiv:2609.35223

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.35223
License (as archived)
CC0-1.0
Archived
2026-10-08T01:37:05.025Z
SHA-256 of the archived text
367b48b355cb52e3539273298c934d27b87089de07ed271678585ca7cca408a3
Stable URL of this page
https://metraipolis.com/documento/dc_d996d9f6db07

How to cite

EMA-Based Subspace Tracking for Adaptive Artifact Subspace Reconstruction — arXiv:2609.35223 — arXiv (en), https://arxiv.org/abs/2609.35223 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d996d9f6db07 (Metraipolis archive dc_d996d9f6db07, sha256 367b48b355cb52e3539273298c934d27b87089de07ed271678585ca7cca408a3)
BibTeX
@misc{dcd996d9f6db07,
  title = {EMA-Based Subspace Tracking for Adaptive Artifact Subspace Reconstruction — arXiv:2609.35223},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.35223},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d996d9f6db07; sha256 367b48b355cb52e3539273298c934d27b87089de07ed271678585ca7cca408a3},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.35223. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Electroencephalogram (EEG) artifact removal remains a critical challenge for real-world brain-computer interface deployment due to non-stationary signal statistics and limited calibration availability. Artifact Subspace Reconstruction (ASR) provides an automated framework for variance-based artifact suppression but relies on a static calibration-derived covariance model, limiting stability under intra-subject drift and increasing sensitivity to parameter mis-specification. This work proposes an adaptive ASR framework based on exponential moving average (EMA) subspace tracking. By integrating short-horizon covariance estimation with slow recursive assimilation, the method establishes dual adaptation timescales that enable responsiveness to evolving EEG structure while preserving stability against transient artifacts. This formulation further promotes smoother operating characteristics across rejection thresholds, reducing sensitivity to hyperparameter selection in continuous deployment settings. Evaluated on 24-channel EEG recordings from 10 subjects with prominent blink artifacts across cognitive states, EMA-ASR achieved substantially stronger artifact attenuation than Original and memory-limited ASR variants (53.1% vs. 24.0% and 26.7% blink reduction), at the cost of increased reconstruction and spectral deviation, whereas the memory-limited variant performed comparably to Original ASR. These findings position EMA-based adaptive tracking as a lightweight, deployment-oriented approach to continuous EEG artifact removal under non-stationary conditions, with an explicit trade-off between suppression strength and signal preservation.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in eess.SP).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2609.35223 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T01:11:02.839Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).