Metraipolis › archive › dc_d99546fc38eb
Instrument-Level Validation of Upper Sideband Syntonization Concept — arXiv:2609.10807
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.10807
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T07:00:41.086Z
- SHA-256 of the archived text
919c4e04b52fd150ccf260156d76cac0fc7f27cb102008da07af93c976eff1b7- Stable URL of this page
https://metraipolis.com/documento/dc_d99546fc38eb
How to cite
Instrument-Level Validation of Upper Sideband Syntonization Concept — arXiv:2609.10807 — arXiv (en), https://arxiv.org/abs/2609.10807 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d99546fc38eb (Metraipolis archive dc_d99546fc38eb, sha256 919c4e04b52fd150ccf260156d76cac0fc7f27cb102008da07af93c976eff1b7)
BibTeX
@misc{dcd99546fc38eb,
title = {Instrument-Level Validation of Upper Sideband Syntonization Concept — arXiv:2609.10807},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.10807},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d99546fc38eb; sha256 919c4e04b52fd150ccf260156d76cac0fc7f27cb102008da07af93c976eff1b7},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10807. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Upper Sideband Syntonization (USBS) is a two-way frequency-transfer concept proposed by the European Space Agency for distributed space radio interferometric systems. Previous investigations validated the concept primarily through frequency-stability and phase-transfer measurements. This work demonstrates the first end-to-end instrument-level validation of the USBS concept through coherent W-band cross-correlation measurements and image reconstruction. A P=2 USBS breadboard was integrated with a W-band radio interferometer developed for this test. The synchronized local oscillators (LOs) were evaluated through long-term cross-correlation measurements and coherent imaging of a point-like noise source. The results were compared with those obtained using a conventional common LO as well as two independent free-running LOs. The USBS-derived LOs maintained coherence over 500 s of cumulative effective integration time acquired over approximately five days of elapsed time and preserved inter-session phase stability over measurements spanning 40 days. The reconstructed image is nearly indistinguishable from that obtained with a common LO, whereas independent free-running LOs lead to severe coherence degradation, image distortion, and approximately 38 dB loss of peak response. The results demonstrate that USBS preserves the interferometric coherence required for W-band imaging and present the first end-to-end instrument-level validation of the USBS syntonization concept for future distributed space radio interferometric missions Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-11 in astro-ph.IM). Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM) ; Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2609.10807 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T06:39:55.812Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).