Metraipolis › archive › dc_d97ef1b9b245
Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift Detection — arXiv:2610.19178
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19178
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T14:15:14.442Z
- SHA-256 of the archived text
f70cb0860e8079232765fae7945dccc9eec8dda90d9d96daf576ffc43d5513f5- Stable URL of this page
https://metraipolis.com/documento/dc_d97ef1b9b245
How to cite
Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift Detection — arXiv:2610.19178 — arXiv (en), https://arxiv.org/abs/2610.19178 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d97ef1b9b245 (Metraipolis archive dc_d97ef1b9b245, sha256 f70cb0860e8079232765fae7945dccc9eec8dda90d9d96daf576ffc43d5513f5)
BibTeX
@misc{dcd97ef1b9b245,
title = {Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift Detection — arXiv:2610.19178},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19178},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d97ef1b9b245; sha256 f70cb0860e8079232765fae7945dccc9eec8dda90d9d96daf576ffc43d5513f5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19178. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Before deploying clinical prediction models, their reliability must be assessed to ensure safe use. Errors may arise from distribution shifts between training and deployment or from heterogeneous performance where the model systematically underperforms for certain patient subgroups. Yet most post-hoc diagnostic methods evaluate reliability only at the population level, checking whether the deployment data resemble the training data and whether the model performs well on average, without accounting for heterogeneity that may cause some patients to be disproportionately affected. We propose a unified diagnostic pipeline that combines both perspectives. MED3pa first discovers interpretable low-confidence patient profiles, and Detectron is then applied within each profile to test whether its degradation is associated with a detectable harmful covariate shift. Across three clinical prediction tasks and three injected subgroup shifts in MIMIC-IV, we find that shift detectability itself is informative. An injected age shift, undetectable at the population level, was nonetheless localized to specific degraded profiles, whereas sex- and race-related shifts were detected broadly and therefore offered little guidance for identifying the most affected patients. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.19178 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T13:53:35.540Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).