Metraipolis › archive › dc_d8fc02acb850
Optimizing GEDI Simulator Configuration for European Temperate Forests — arXiv:2609.11440
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.11440
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T05:59:55.706Z
- SHA-256 of the archived text
72a273d0ac8bcad508f8308ab2eb40424b4fb606dafe9307e9a86b98e1e36d37- Stable URL of this page
https://metraipolis.com/documento/dc_d8fc02acb850
How to cite
Optimizing GEDI Simulator Configuration for European Temperate Forests — arXiv:2609.11440 — arXiv (en), https://arxiv.org/abs/2609.11440 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d8fc02acb850 (Metraipolis archive dc_d8fc02acb850, sha256 72a273d0ac8bcad508f8308ab2eb40424b4fb606dafe9307e9a86b98e1e36d37)
BibTeX
@misc{dcd8fc02acb850,
title = {Optimizing GEDI Simulator Configuration for European Temperate Forests — arXiv:2609.11440},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.11440},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d8fc02acb850; sha256 72a273d0ac8bcad508f8308ab2eb40424b4fb606dafe9307e9a86b98e1e36d37},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.11440. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Accurate estimation of aboveground biomass density is essential for quantifying forest carbon stocks. NASA's GEDI mission provides valuable canopy structure data, but its sparse sampling necessitates the use of simulators to calibrate biomass models at field inventory locations. The widely used simulator of Hancock et al. (2019) emulates GEDI waveforms from airborne LiDAR point clouds, yet it has never been validated over European temperate forests. Here, we compare approximately 9,500 pairs of observed and simulated GEDI relative height (RH) profiles across French forests using the national airborne LiDAR program as input. We separate two sources of error: waveform modeling differences, assessed by referencing both simulated and real RH metrics to a common ALS-derived ground elevation, and ground detection bias, evaluated by comparing each GEDI L2A processing algorithm against the ALS reference. Under the baseline configuration, the mean absolute bias across the full RH profile reaches 0.69 m in leaf-on and 1.28 m in leaf-off conditions. Switching to intensity-based return weighting and selecting the a3 L2A algorithm reduces these biases to 0.44 m and 0.40 m respectively. The a3 algorithm also achieves near-unbiased ground detection (-0.03 m versus -0.88 m for the default), directly reducing a previously overlooked source of error. We also show that leaf-off acquisitions and low-sensitivity shots, both typically excluded from standard biomass products, are simulated as reliably as their counterparts, substantially expanding the potential calibration and inference datasets. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-11 in stat.AP). Categorie arXiv: Signal Processing (eess.SP) ; Geophysics (physics.geo-ph); Applications (stat.AP); Computation (stat.CO). Pagina del lavoro: https://arxiv.org/abs/2609.11440 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T05:49:37.475Z dalla pagina https://arxiv.org/catchup/stat.AP/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).