Metraipolis › archive › dc_d8d1f0daeb2c
MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation — arXiv:2610.04036
- Source
- arXiv
- Original
- https://arxiv.org/abs/2610.04036
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-06T05:25:55.665Z
- SHA-256 of the archived text
ab4dba27c5591446bc3fa1b2acc56c4c7d44c0b0b6775cbbd3239f73b47ff712- Stable URL of this page
https://metraipolis.com/documento/dc_d8d1f0daeb2c
How to cite
MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation — arXiv:2610.04036 — arXiv, https://arxiv.org/abs/2610.04036 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d8d1f0daeb2c (Metraipolis archive dc_d8d1f0daeb2c, sha256 ab4dba27c5591446bc3fa1b2acc56c4c7d44c0b0b6775cbbd3239f73b47ff712)
BibTeX
@misc{dcd8d1f0daeb2c,
title = {MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation — arXiv:2610.04036},
howpublished = {arXiv},
url = {https://arxiv.org/abs/2610.04036},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d8d1f0daeb2c; sha256 ab4dba27c5591446bc3fa1b2acc56c4c7d44c0b0b6775cbbd3239f73b47ff712},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv, https://arxiv.org/abs/2610.04036. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.04036 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-06T05:24:05.773Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).