Metraipolis › archive › dc_d83c225d7916
Passive LWIR Hyperspectral Ranging via Transmittance Extraction and Distance Alignment — arXiv:2609.28967
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.28967
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T06:44:19.432Z
- SHA-256 of the archived text
f4399b338d9f669d63f8ae59698dc1f8de2da8de6fbac99c7892b2dc6eeeb596- Stable URL of this page
https://metraipolis.com/documento/dc_d83c225d7916
How to cite
Passive LWIR Hyperspectral Ranging via Transmittance Extraction and Distance Alignment — arXiv:2609.28967 — arXiv (en), https://arxiv.org/abs/2609.28967 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d83c225d7916 (Metraipolis archive dc_d83c225d7916, sha256 f4399b338d9f669d63f8ae59698dc1f8de2da8de6fbac99c7892b2dc6eeeb596)
BibTeX
@misc{dcd83c225d7916,
title = {Passive LWIR Hyperspectral Ranging via Transmittance Extraction and Distance Alignment — arXiv:2609.28967},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.28967},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d83c225d7916; sha256 f4399b338d9f669d63f8ae59698dc1f8de2da8de6fbac99c7892b2dc6eeeb596},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.28967. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Passive long-wave infrared (LWIR) hyperspectral ranging enables distance estimation in low-light and nighttime scenes by exploiting atmospheric absorption features in thermal radiance received through the this http URL estimation of temperature, emissivity, and distance is computationally expensive. Reference-range joint inversion also uses a distance-invariant effective attenuation coefficient, which can bias range this http URL introduce transmittance extraction and distance alignment (TEDA), which decouples range estimation from temperature--emissivity inversion. In the first stage, a baseline estimator with a data-fidelity term invariant to the known absorption direction yields two closed-form smoothing branches for the slowly varying thermal continuum. An observation-derived gate combines the branches, and subtracting the blended baseline in the log domain recovers atmospheric transmittance. The second stage estimates range by matching the recovered transmittance to sensor-domain transmittance models recomputed for each candidate distance. Monte Carlo simulations show that TEDA effectively reduces the ranging bias caused by the distance-invariant attenuation coefficient approximation. In a measured scene, TEDA's mean range estimates are closer to the LiDAR medians than those of reference-range joint inversion in both evaluated patches. TEDA processes a complete $256\times256$ region of interest in 8.19~s versus 159.47~s for reference-range joint inversion, an approximately 20-fold speedup. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-25 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.28967 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T06:09:29.803Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).