Metraipolis › archive › dc_d82f125d3305

Optimal Heat Storage Sizing for District Heating Networks to Maximize Electricity Revenue from Combined Heat and Power Units — arXiv:2608.12525

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.12525
License (as archived)
CC0-1.0
Archived
2026-10-19T04:46:21.651Z
SHA-256 of the archived text
b2fc6061c94e0482d6babad28f7bcc08cfc66e10507547e061ea35249aff3fec
Stable URL of this page
https://metraipolis.com/documento/dc_d82f125d3305

How to cite

Optimal Heat Storage Sizing for District Heating Networks to Maximize Electricity Revenue from Combined Heat and Power Units — arXiv:2608.12525 — arXiv (en), https://arxiv.org/abs/2608.12525 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d82f125d3305 (Metraipolis archive dc_d82f125d3305, sha256 b2fc6061c94e0482d6babad28f7bcc08cfc66e10507547e061ea35249aff3fec)
BibTeX
@misc{dcd82f125d3305,
  title = {Optimal Heat Storage Sizing for District Heating Networks to Maximize Electricity Revenue from Combined Heat and Power Units — arXiv:2608.12525},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.12525},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d82f125d3305; sha256 b2fc6061c94e0482d6babad28f7bcc08cfc66e10507547e061ea35249aff3fec},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.12525. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Integrating heat storages in district heating networks (DHNs) supports managing dynamic characteristics such as heat-demand variations and changing energy prices, and the intermittency of renewable sources. A common application are DHNs with combined heat and power (CHP) units, where a storage allows shifting heat extraction to periods with favorable electricity prices. Although the benefits of heat storage in DHNs are well established, determining the optimal storage size remains challenging due to the diversity of DHNs in terms of heat sources, production and consumption patterns, network heat losses, and fuel costs. This paper presents a scalable, automated methodology for optimizing short-term heat storage in DHNs using mathematical optimization. The nonlinear, physics-based approach models the DHN, heat producers, and storages simultaneously to minimize total economic cost through optimal storage sizing, explicitly considering time-varying heat-production costs, heat demands, and heat losses. The methodology is demonstrated on a 3rd-generation CHP-DHN in Belgium with 30 consumers, exceeding the scale of previous physics-based storage-sizing studies. For this system, optimal storage integration reduces the 20-year cost by 730 k EUR (16.5%), from 4.41 M EUR to 3.68 M EUR. The reduction results from a 1.07 M EUR decrease in heat-production cost achieved by shifting heat extraction to periods of low electricity prices, while the storage investment amounts to 323 k EUR. A comparison to a commonly used simplified storage sizing method, which fails to identify the optimal storage size, demonstrates the advantage of the proposed holistic, physics-based optimization approach in ensuring feasible designs, accurate cost assessments, and optimal storage sizing.

Tema degli esploratori: matematica e informatica teorica (retro-catalogo arXiv: annunci del 2026-08-14 in math.OC).
Categorie arXiv: Optimization and Control (math.OC).
Pagina del lavoro: https://arxiv.org/abs/2608.12525 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T04:27:11.015Z dalla pagina https://arxiv.org/catchup/math.OC/2026-08-14?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).