Metraipolis › archive › dc_d752c5933775

Trials of the Automated Particle Counter for laboratory rearing of mosquito larvae — Europe PMC PMID:33170865

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/33170865
DOI
10.1371/journal.pone.0241492
License (as archived)
CC0-1.0
Archived
2026-11-06T23:10:58.166Z
SHA-256 of the archived text
981ab61cc21f0eacc52bf8524ab1f85df241de2163b1bee74ca6274b26767fb8
Stable URL of this page
https://metraipolis.com/documento/dc_d752c5933775

How to cite

Trials of the Automated Particle Counter for laboratory rearing of mosquito larvae — Europe PMC PMID:33170865 — Europe PMC (en), https://europepmc.org/article/MED/33170865 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d752c5933775 (Metraipolis archive dc_d752c5933775, sha256 981ab61cc21f0eacc52bf8524ab1f85df241de2163b1bee74ca6274b26767fb8)
BibTeX
@misc{dcd752c5933775,
  title = {Trials of the Automated Particle Counter for laboratory rearing of mosquito larvae — Europe PMC PMID:33170865},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/33170865},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d752c5933775; sha256 981ab61cc21f0eacc52bf8524ab1f85df241de2163b1bee74ca6274b26767fb8},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/33170865. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

As a means of obtaining reproducible and accurate numbers of larvae for laboratory rearing, we tested a large-particle flow-cytometer type device called the 'Automated Particle Counter' (APC). The APC is a gravity-fed, self-contained unit that detects changes in light intensity caused by larvae passing the detector in a water stream and controls dispensing by stopping the flow when the desired number has been reached. We determined the accuracy (number dispensed compared to the target value) and precision (distribution of number dispensed) of dispensing at a variety of counting sensitivity thresholds and larva throughput rates (larvae per second) using < 1-day old Anopheles gambiae and Aedes aegypti larvae. All measures were made using an APC algorithm called the 'Smoothed Z-Score' which allows the user to define how many standard deviations (Z scores) from the baseline light intensity a particle's absorbance must exceed to register a count. We dispensed a target number of 100 An. gambiae larvae using Z scores from 2.5-8 and observed no difference among them in the numbers dispensed for scores from 2.5-6, however, scores of 7 and 8 under-counted (over-dispensed) larvae. Using a Z score ≤ 6, we determined the effect of throughput rate on the accuracy of the device to dispense An. gambiae larvae. For rates ≤ 98 larvae per second, the accuracy of dispensing a target of 100 larvae was - 2.29% ± 0.72 (95% CI of the mean) with a mode of 99 (49 of 348 samples). When using a Z score of 3.5 and rates ≤ 100 larvae per second, the accuracy of dispensing a target of 100 Ae. aegypti was - 2.43% ± 1.26 (95% CI of the mean) with a mode of 100 (6 of 42 samples). No effect on survival was observed on the number of An. gambiae first stage larvae that reached adulthood as a function of dispensing.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-11-10).
Identificativi: PMID 33170865 · PMCID PMC7654806 · DOI 10.1371/journal.pone.0241492.
Descrittori MeSH principali: Laboratories.
Pagina: https://europepmc.org/article/MED/33170865 — https://doi.org/10.1371/journal.pone.0241492. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-11-06T23:07:18.235Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.