Metraipolis › archive › dc_d71082663b31

Beyond Accuracy: Counterfactual Fragility and Demographic Bias in Clinical Evaluation of LLMs — arXiv:2609.32807

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.32807
License (as archived)
CC0-1.0
Archived
2026-10-07T20:56:09.653Z
SHA-256 of the archived text
b474b306effa0128b316c549e8306aa960024715b37040d33548f82cf3cb0ac0
Stable URL of this page
https://metraipolis.com/documento/dc_d71082663b31

How to cite

Beyond Accuracy: Counterfactual Fragility and Demographic Bias in Clinical Evaluation of LLMs — arXiv:2609.32807 — arXiv (en), https://arxiv.org/abs/2609.32807 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d71082663b31 (Metraipolis archive dc_d71082663b31, sha256 b474b306effa0128b316c549e8306aa960024715b37040d33548f82cf3cb0ac0)
BibTeX
@misc{dcd71082663b31,
  title = {Beyond Accuracy: Counterfactual Fragility and Demographic Bias in Clinical Evaluation of LLMs — arXiv:2609.32807},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.32807},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d71082663b31; sha256 b474b306effa0128b316c549e8306aa960024715b37040d33548f82cf3cb0ac0},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.32807. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Clinical LLM evaluation often emphasizes answer accuracy; however, accuracy alone does not test counterfactual consistency or demographic robustness. We evaluated six LLMs on 150 MedQA USMLE questions using two automated perturbation tests to assess their performance. The counterfactual validity (CFV) test asked each model to make a minimal, plausible clinical change that would make a different answer correct. The demographic robustness test added six demographic prefixes to the same vignette and compared the answers and explanations with a no demographic baseline. Of the 900 CFV attempts, 228 (25.3 %) were valid and 672 were invalid. Across 5,400 demographic comparisons, 1,097 answers were changed (20.3%). Automated judging identified 3,128 stereotype evidence flags, including 1,932 in the broad Other category. MedGemma 27B achieved the highest accuracy (87.1%) and CFV (63.3%), lowest answer change rate (16.0%), and low mean Explanation Demographic Dissonance (EDD) score (0.169). However, its accuracy still exceeded its CFV, indicating that correct answers do not guarantee reliable performance on the counterfactual validity task. OpenBioLLM had the highest answer change rate and EDD, whereas GLM had the highest stereotype flag rate. These findings show that accuracy, CFV, answer stability, EDD, and stereotype evidence capture different evaluation aspects. Because all judgments were automated and no clinician validation was available, the results support safety screening but do not establish clinical deployability of the model.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.32807 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T20:29:01.000Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).