Metraipolis › archive › dc_d694e2c895f2

Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers — arXiv:2611.01790

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.01790
License (as archived)
CC0-1.0
Archived
2026-11-03T11:25:11.022Z
SHA-256 of the archived text
776662c6f5c592505bc9bb8f5c30be2eb3d1a4ee3d92103f40cebd614860817e
Stable URL of this page
https://metraipolis.com/documento/dc_d694e2c895f2

How to cite

Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers — arXiv:2611.01790 — arXiv (en), https://arxiv.org/abs/2611.01790 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d694e2c895f2 (Metraipolis archive dc_d694e2c895f2, sha256 776662c6f5c592505bc9bb8f5c30be2eb3d1a4ee3d92103f40cebd614860817e)
BibTeX
@misc{dcd694e2c895f2,
  title = {Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers — arXiv:2611.01790},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.01790},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d694e2c895f2; sha256 776662c6f5c592505bc9bb8f5c30be2eb3d1a4ee3d92103f40cebd614860817e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01790. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: this http URL

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Machine Learning (cs.LG); Medical Physics (physics.med-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.01790 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T11:02:37.833Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).