Metraipolis › archive › dc_d537bd0bf74c
Scene Graph-Driven Haptic Feedback for Safety Enhancement in Robotic Ophthalmic Surgery via Physically Simulated iOCT — arXiv:2609.07857
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.07857
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T15:12:46.218Z
- SHA-256 of the archived text
3caa850e3c8cb38912a01715e98ba12c614381a67b18fb05989a32b859fbad56- Stable URL of this page
https://metraipolis.com/documento/dc_d537bd0bf74c
How to cite
Scene Graph-Driven Haptic Feedback for Safety Enhancement in Robotic Ophthalmic Surgery via Physically Simulated iOCT — arXiv:2609.07857 — arXiv (en), https://arxiv.org/abs/2609.07857 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d537bd0bf74c (Metraipolis archive dc_d537bd0bf74c, sha256 3caa850e3c8cb38912a01715e98ba12c614381a67b18fb05989a32b859fbad56)
BibTeX
@misc{dcd537bd0bf74c,
title = {Scene Graph-Driven Haptic Feedback for Safety Enhancement in Robotic Ophthalmic Surgery via Physically Simulated iOCT — arXiv:2609.07857},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.07857},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d537bd0bf74c; sha256 3caa850e3c8cb38912a01715e98ba12c614381a67b18fb05989a32b859fbad56},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.07857. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Robotic ophthalmic surgery offers high precision but introduces a "sensory gap" by decoupling the surgeon from their instrument, resulting in a loss of tactile feedback. This paper presents a novel haptic feedback system for subretinal injection tasks leveraging Scene Graphs (SG). The system bridges the sensory gap by analyzing a physically simulated intraoperative Optical Coherence Tomography (iOCT) feed to construct a real-time surgical SG. The SG serves as a semantic abstraction layer for the surgical scene, which is then utilized by a deterministic, rule-based engine to generate state-dependent haptic feedback on a robotic input device. The system was evaluated in a user study (N=16) using an anthropomorphic head phantom and a custom-built surgical robot. Results demonstrate that the SG-driven haptic feedback improved surgical precision, reducing needle alignment error by 14% (p = 0.044) and improving System Usability Scale (SUS) scores by 8% (p = 0.015), while maintaining comparable task completion times. A needle trajectory analysis revealed the emergence of a safer "Align-then-Approach" strategy, in which our haptic negative reinforcement prompted users to fine-tune the tool's trajectory before approaching the retinal target. This work suggests that SGs can effectively serve as the direct computational foundation for real-time, safety-enhancing context-aware haptic feedback in robotic microsurgery. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-09 in cs.CV). Categorie arXiv: Robotics (cs.RO) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.07857 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T14:49:57.438Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).