Metraipolis › archive › dc_d4508bf021d3

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction — arXiv:2610.40478

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.40478
License (as archived)
CC0-1.0
Archived
2026-11-01T02:42:26.723Z
SHA-256 of the archived text
0c102071b624a1ca0a10d0dc970860988de2475ee4dd9fc880ccd35013fe26bc
Stable URL of this page
https://metraipolis.com/documento/dc_d4508bf021d3

How to cite

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction — arXiv:2610.40478 — arXiv (en), https://arxiv.org/abs/2610.40478 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d4508bf021d3 (Metraipolis archive dc_d4508bf021d3, sha256 0c102071b624a1ca0a10d0dc970860988de2475ee4dd9fc880ccd35013fe26bc)
BibTeX
@misc{dcd4508bf021d3,
  title = {Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction — arXiv:2610.40478},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.40478},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d4508bf021d3; sha256 0c102071b624a1ca0a10d0dc970860988de2475ee4dd9fc880ccd35013fe26bc},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.40478. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On $^{11}$C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE $0.016 \pm 0.015$, Pearson $r = 0.9987$) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.40478 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:16:43.988Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).