Metraipolis › archive › dc_d2e9740c18c5

Where Should the Gaussians Go? Reusable Label-Aware Allocation for Budget-Constrained Gaussian Splatting of Cinematic CT — arXiv:2610.20397

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.20397
License (as archived)
CC0-1.0
Archived
2026-10-15T21:57:17.805Z
SHA-256 of the archived text
6e5c85db5458867ac85ae9086e2bc394b6cea362a0aa34834dd329e435cf561c
Stable URL of this page
https://metraipolis.com/documento/dc_d2e9740c18c5

How to cite

Where Should the Gaussians Go? Reusable Label-Aware Allocation for Budget-Constrained Gaussian Splatting of Cinematic CT — arXiv:2610.20397 — arXiv (en), https://arxiv.org/abs/2610.20397 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d2e9740c18c5 (Metraipolis archive dc_d2e9740c18c5, sha256 6e5c85db5458867ac85ae9086e2bc394b6cea362a0aa34834dd329e435cf561c)
BibTeX
@misc{dcd2e9740c18c5,
  title = {Where Should the Gaussians Go? Reusable Label-Aware Allocation for Budget-Constrained Gaussian Splatting of Cinematic CT — arXiv:2610.20397},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.20397},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d2e9740c18c5; sha256 6e5c85db5458867ac85ae9086e2bc394b6cea362a0aa34834dd329e435cf561c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.20397. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Anatomical labels help 3D Gaussian splatting preserve vessels in cinematic renderings of CT, but the representation is still found by optimising each patient's scene, where densification decides where Gaussians go, while real-time displays cap their number. We address one part of this process: deciding where a fixed budget of B Gaussians should be placed. We propose a reusable, labelaware allocation front end that maps a patient's CT, labels and transfer function to a density over 2mm cells and draws exactly B positions from it without per-patient optimisation; the other Gaussian attributes are still fitted per patient. The front end is learned once from per-patient optimised scenes and implemented as a population-trained neural prior and an interpretable seven-parameter visibility-aware closed form (VACF). With identical attribute fitting on 20 held-out patients at 10K-100K Gaussians, both raise vessel-masked PSNR over uniform allocation by 4.5-7.1dB and over pruning a dense voxel-aligned model by 1.6-3.3dB. The neural prior does not differ significantly from per-patient optimised allocation at any budget, and VACF is within 0.6dB of it on vessels; on 19 external patients the neural prior again matches it on vessels and VACF is within 0.7dB. As an initialisation for position optimisation, VACF allocation beats per-patient densification on vessels at 10K Gaussians and, at 25K, reaches a higher vessel PSNR after 118s of optimisation than densification after 248s. Under altered rendering presets, VACF transfers to new colours and lighting but not to a label-free transfer function, whereas the neural prior shows the opposite pattern.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.20397 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T21:38:29.538Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).