Metraipolis › archive › dc_d0f5be244744
RECAST: Recent & Context-Aware Sampling for Test-Time Adaptation in Streaming Biosignals — arXiv:2608.28271
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28271
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T10:47:33.379Z
- SHA-256 of the archived text
fc36e6d2bb9146e87789458a45242a9f922619f1e79ed4b074a7a06e0b7088d5- Stable URL of this page
https://metraipolis.com/documento/dc_d0f5be244744
How to cite
RECAST: Recent & Context-Aware Sampling for Test-Time Adaptation in Streaming Biosignals — arXiv:2608.28271 — arXiv (en), https://arxiv.org/abs/2608.28271 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d0f5be244744 (Metraipolis archive dc_d0f5be244744, sha256 fc36e6d2bb9146e87789458a45242a9f922619f1e79ed4b074a7a06e0b7088d5)
BibTeX
@misc{dcd0f5be244744,
title = {RECAST: Recent & Context-Aware Sampling for Test-Time Adaptation in Streaming Biosignals — arXiv:2608.28271},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28271},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d0f5be244744; sha256 fc36e6d2bb9146e87789458a45242a9f922619f1e79ed4b074a7a06e0b7088d5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28271. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Streaming biosignals vary across subjects and drift over time, so population-trained models lose accuracy during long-term monitoring. Test-time adaptation (TTA) enables online personalization by updating the model on incoming samples. But in a stream, a basic question is left open: \emph{which samples should drive each update?} Using all buffered samples blurs the update with irrelevant segments. Using only the latest segment makes the update noisy and unstable. The most useful samples are recent, aligned with the current physiological state, and reliable enough to learn from. We propose \textbf{RECAST} (REcent \& Context-Aware Sampling for TTA), a lightweight sampling module for buffered TTA frameworks. RECAST builds each adaptation batch from three signals: temporal recency, contextual similarity, and predictive reliability. It changes only which samples are used, leaving the model and the training objective unchanged. On two blood-pressure datasets, RECAST improves estimation accuracy and trend tracking over baselines and ablations. The per-patient gains are statistically significant on both datasets, with broad improvement on the regular benchmark and gains concentrated on the hardest patients in the emergency-department setting. RECAST stays practical, adding only sub-second latency per segment on a single GPU and CPU core.
Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-31 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.28271 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T10:33:42.412Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-31?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).