Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification — arXiv:2609.08081
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.08081
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T16:38:02.889Z
- SHA-256 of the archived text
f4dea4631f0c233b826b450580be61d649637aa72618dd784f1f348df7ec9bcd- Stable URL of this page
https://metraipolis.com/documento/dc_d0da9e00d8fe
How to cite
Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification — arXiv:2609.08081 — arXiv (en), https://arxiv.org/abs/2609.08081 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_d0da9e00d8fe (Metraipolis archive dc_d0da9e00d8fe, sha256 f4dea4631f0c233b826b450580be61d649637aa72618dd784f1f348df7ec9bcd)
BibTeX
@misc{dcd0da9e00d8fe,
title = {Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification — arXiv:2609.08081},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.08081},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_d0da9e00d8fe; sha256 f4dea4631f0c233b826b450580be61d649637aa72618dd784f1f348df7ec9bcd},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.08081. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Background: This study evaluated interreader agreement and longitudinal performance of MRI methods for knee cartilage volume, thickness, and defect-area quantification. Methods: AI-presegmented masks from 1,189 phase III examinations underwent independent correction by two readers and adjudication. Cartilage volume, three-dimensional ray-tracing thickness (3D-RT), and ray-based defect area (3D-RBA), defined by a 1.5-mm thickness threshold, were calculated. Agreement was assessed using segmentation metrics, intraclass correlation coefficients (ICCs), repeated-measures Bland-Altman analysis, and minimal detectable change at 95% confidence (MDC95). The 3D-RBA framework was evaluated in 120 digital-phantom experiments from 40 participants. Longitudinal analyses included 374 participants, alternative-method comparisons included 65, and retrospective phase II analysis included 24 participants with four visits. Results: Overall AI-to-adjudicated-mask Dice was 0.964 +/- 0.029. Interreader ICCs for volume, thickness, and defect area were 0.956, 0.904, and 0.932; corresponding MDC95 values were 1,596.9 mm^3, 0.227 mm, and 147.4 mm^2. Geometric mean absolute percentage error for defect area was 5.62%, with spatial Dice of 0.961. In 374 participants, volume changes correlated positively with thickness changes (rho=0.431) and negatively with defect-area changes (rho=-0.221). Within-participant phase II correlations followed the same directions in both groups. Conclusions: The workflow demonstrated good interreader agreement. Controlled geometric results and longitudinal associations supported the feasibility of threshold-based defect-area estimation. Volume, thickness, and defect area provide complementary measures of cartilage structure. Tema degli esploratori: scienze della vita e salute (retro-catalogo arXiv: annunci del 2026-09-09 in q-bio.QM). Categorie arXiv: Image and Video Processing (eess.IV) ; Quantitative Methods (q-bio.QM). Pagina del lavoro: https://arxiv.org/abs/2609.08081 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T16:07:25.386Z dalla pagina https://arxiv.org/catchup/q-bio.QM/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).