Metraipolis › archive › dc_cfd821b44ca0
TinyCardioUNet: IMU-to-ECG Translation with Graph-Encoded Inter-Axis Dependencies and Tensor Decomposition-Based Parameter Reduction — arXiv:2609.29322
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.29322
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T05:25:57.027Z
- SHA-256 of the archived text
a6bb8fde355d56ad8fd26e78439136b09531631f9c7ebb7c96125b566d969e76- Stable URL of this page
https://metraipolis.com/documento/dc_cfd821b44ca0
How to cite
TinyCardioUNet: IMU-to-ECG Translation with Graph-Encoded Inter-Axis Dependencies and Tensor Decomposition-Based Parameter Reduction — arXiv:2609.29322 — arXiv (en), https://arxiv.org/abs/2609.29322 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cfd821b44ca0 (Metraipolis archive dc_cfd821b44ca0, sha256 a6bb8fde355d56ad8fd26e78439136b09531631f9c7ebb7c96125b566d969e76)
BibTeX
@misc{dccfd821b44ca0,
title = {TinyCardioUNet: IMU-to-ECG Translation with Graph-Encoded Inter-Axis Dependencies and Tensor Decomposition-Based Parameter Reduction — arXiv:2609.29322},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.29322},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cfd821b44ca0; sha256 a6bb8fde355d56ad8fd26e78439136b09531631f9c7ebb7c96125b566d969e76},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.29322. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Estimating electrocardiography (ECG) from a chest-worn inertial measurement unit (IMU) enables continuous heart rate (HR) monitoring without the discomfort of electrodes. We propose TinyCardioUNet, a lightweight UNet that uses all six IMU axes without prior channel selection, refines its bottleneck with a graph neural network that encodes inter-axis dependencies, and employs tensor decomposition with automatic variational Bayesian rank selection for parameter reduction. On a public dataset, TinyCardioUNet achieves an RMSE of $0.098$ and a Pearson correlation coefficient of $0.677$ with only $36.0$k parameters and remains comparatively robust to additive noise, demonstrating accurate ECG reconstruction with a compact model. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-25 in cs.LG). Categorie arXiv: Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2609.29322 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T04:50:39.355Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).