Metraipolis › archive › dc_cf162ed62651
Headroom-Aware Stochastic Adaptive Model Predictive Control for Load Frequency Control in Microgrids — arXiv:2609.05332
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.05332
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T00:41:04.134Z
- SHA-256 of the archived text
8527db2cc57755c65b8eec38af8e3a381dd1be62436c529acdfb610509e73fc1- Stable URL of this page
https://metraipolis.com/documento/dc_cf162ed62651
How to cite
Headroom-Aware Stochastic Adaptive Model Predictive Control for Load Frequency Control in Microgrids — arXiv:2609.05332 — arXiv (en), https://arxiv.org/abs/2609.05332 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cf162ed62651 (Metraipolis archive dc_cf162ed62651, sha256 8527db2cc57755c65b8eec38af8e3a381dd1be62436c529acdfb610509e73fc1)
BibTeX
@misc{dccf162ed62651,
title = {Headroom-Aware Stochastic Adaptive Model Predictive Control for Load Frequency Control in Microgrids — arXiv:2609.05332},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.05332},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cf162ed62651; sha256 8527db2cc57755c65b8eec38af8e3a381dd1be62436c529acdfb610509e73fc1},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.05332. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
As the penetration of inverter-based resources (IBRs) increases in microgrids, they are increasingly expected to play a greater role in load frequency control (LFC). Model predictive control (MPC) is attractive for LFC because it incorporates system dynamics and operational constraints. However, most MPC-based LFC formulations rely on fixed reserve headroom based on forecasted renewable availability or storage systems. Under short-term renewable intermittency, IBR headroom is stochastic and time-varying, causing optimal control commands to exceed the physically deliverable regulation capability and cause stochastic saturation. This control-actuator mismatch degrades LFC performance. Accordingly, this study develops two headroom-aware strategies for PV-dominated microgrids. First, stochastic headroom constrained MPC (SHCMPC) incorporates headroom predictions through time-varying input constraints to enforce control feasibility. Second, stochastic adaptive MPC (SAMPC) embeds headroom awareness into the MPC objective function by adaptively penalizing control actions based on predicted headroom, reducing reliance on units with limited headroom without hard time-varying constraints. Simulation results show that stochastic saturation degrades conventional MPC-based LFC, particularly under tight reserve margins. Both strategies improve regulation performance. SHCMPC eliminates saturation events, while SAMPC achieves substantial saturation mitigation with lower computational effort, offering a computationally efficient alternative for real-time LFC under stochastic renewable availability. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-07 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.05332 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T00:12:32.321Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).