Metraipolis › archive › dc_cf096e049369

Nationally Consistent, Locally Incomplete: A Bayesian Remote-Sensing Audit of Rooftop Photovoltaic Registries — arXiv:2609.16294

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.16294
License (as archived)
CC0-1.0
Archived
2026-10-15T19:36:07.021Z
SHA-256 of the archived text
eb301d65e95337ff0cf6cf59b46a7e0e3fbfddb748b9695ce7abbf09fa2bf5ab
Stable URL of this page
https://metraipolis.com/documento/dc_cf096e049369

How to cite

Nationally Consistent, Locally Incomplete: A Bayesian Remote-Sensing Audit of Rooftop Photovoltaic Registries — arXiv:2609.16294 — arXiv (en), https://arxiv.org/abs/2609.16294 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cf096e049369 (Metraipolis archive dc_cf096e049369, sha256 eb301d65e95337ff0cf6cf59b46a7e0e3fbfddb748b9695ce7abbf09fa2bf5ab)
BibTeX
@misc{dccf096e049369,
  title = {Nationally Consistent, Locally Incomplete: A Bayesian Remote-Sensing Audit of Rooftop Photovoltaic Registries — arXiv:2609.16294},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.16294},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cf096e049369; sha256 eb301d65e95337ff0cf6cf59b46a7e0e3fbfddb748b9695ce7abbf09fa2bf5ab},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.16294. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Tracking the energy transition requires reliable statistics on renewable deployment. Rooftop photovoltaics (PV) are especially hard to track, owing to their decentralised nature, and the resulting inaccuracies in official statistics are known but not quantified. Remote sensing offers an independent way to identify rooftop PV systems. We introduce a Bayesian framework to estimate the ground-truth rooftop PV capacity from remote sensing detections, turning an imperfect detector into an uncertainty-aware measurement instrument. Applied to France, the corrected detections estimate a capacity of 4.03 GWp [3.96--4.11] (99% credible interval) of rooftop PV below 36 kWp, matching the transmission system operator's connection data within 3.3% nationally, while identifying local under-reports of up to 61% of local capacity. We also document and quantify a significant truncation bias in French rooftop PV open data. Beyond France, the approach paves the way for more reliable estimates of rooftop PV capacity worldwide.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-16 in stat.AP).
Categorie arXiv: Applications (stat.AP) ; Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.16294 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T19:35:35.031Z dalla pagina https://arxiv.org/catchup/stat.AP/2026-09-16?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).