Metraipolis › archive › dc_cf08dcb6ab82
Nano differential scanning fluorimetry — Wikipedia (en)
- Source
- Wikipedia (en)
- Original
- https://en.wikipedia.org/wiki/Nano_differential_scanning_fluorimetry
- License (as archived)
- CC-BY-SA-4.0
- Archived
- 2026-10-08T00:01:10.277Z
- SHA-256 of the archived text
517aa70b71dda5f18d40067f5a52063a484af4a4a5ee34d833567aa5f1520349- Stable URL of this page
https://metraipolis.com/documento/dc_cf08dcb6ab82
How to cite
Nano differential scanning fluorimetry — Wikipedia (en) — Wikipedia (en), https://en.wikipedia.org/wiki/Nano_differential_scanning_fluorimetry (CC-BY-SA-4.0); archived copy: https://metraipolis.com/documento/dc_cf08dcb6ab82 (Metraipolis archive dc_cf08dcb6ab82, sha256 517aa70b71dda5f18d40067f5a52063a484af4a4a5ee34d833567aa5f1520349)
BibTeX
@misc{dccf08dcb6ab82,
title = {Nano differential scanning fluorimetry — Wikipedia (en)},
howpublished = {Wikipedia (en)},
url = {https://en.wikipedia.org/wiki/Nano_differential_scanning_fluorimetry},
note = {License CC-BY-SA-4.0; archived copy https://metraipolis.com/documento/dc_cf08dcb6ab82; sha256 517aa70b71dda5f18d40067f5a52063a484af4a4a5ee34d833567aa5f1520349},
year = {2026}
}Archived text
Reproduced under CC-BY-SA-4.0. Attribution: Wikipedia (en), https://en.wikipedia.org/wiki/Nano_differential_scanning_fluorimetry. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
NanoDSF is a type of differential scanning fluorimetry (DSF) method used to determine conformational protein stability by employing intrinsic tryptophan or tyrosine fluorescence, as opposed to the use of extrinsic fluorogenic dyes that are typically monitored via a qPCR instrument. A nanoDSF assay is also known as a type of Thermal Shift Assay. Protein stability is typically addressed by thermal or chemical unfolding experiments. In thermal unfolding experiments, a linear temperature ramp is applied to unfold proteins, whereas chemical unfolding experiments use chemical denaturants in increasing concentrations. The thermal stability of a protein is typically described by the 'melting temperature' or 'Tm', at which 50% of the protein population is unfolded, corresponding to the midpoint of the transition from folded to unfolded. In contrast to conventional DSF methods, nanoDSF uses tryptophan or tyrosine fluorescence to monitor protein unfolding. Both the fluorescence intensity and the fluorescence maximum strongly depend on the close chemical environment of the tryptophan. Typically, interior tryptophan residues in a more hydrophobic environment exhibit a notable emission red shift from approximately 330 nm to 350 nm upon protein unfolding and exposure to water. Quantification of these fluorescence wavelength shifts at various temperature intervals yields a measurement of Tm. Accepted methods to detect and quantify the fluorescence wavelength shift include measuring the intensity at a single wavelength, computing a ratio of the intensity at two wavelengths (typically 330 nm and 350 nm), or calculating the barycentric mean (BCM) by measuring the center of mass of the fluorescence waveform. The latter BCM method takes advantage of the entire UV-fluorescence spectrum, thus allowing for flexibility when auto-fluorescent small molecules are present. Applications of nanoDSF include protein or antibody engineering, membrane protein research, quality control and formulation development, and ligand binding. NanoDSF has also been utilized to rapidly evaluate the melting points of enzyme libraries for biotechnological applications. Currently there are at least four instruments on the market that can measure fluorescence wavelength shifts in a high-throughput manner while heating the samples through a defined temperature ramp. These instruments employ either proprietary quartz capillaries, cartridges, or plates or generic high-throughput 384-well plastic plates for sample analysis. Tema degli esploratori: scienze della vita e salute (deposito sistematico; categoria «Molecular biology»). Fonte: Wikipedia in inglese, voce «Nano differential scanning fluorimetry» — https://en.wikipedia.org/wiki/Nano_differential_scanning_fluorimetry Wikidata Q25111277 (dati Wikidata in CC0 1.0) — https://www.wikidata.org/wiki/Q25111277 Autori: i contributori di Wikipedia (cronologia: https://en.wikipedia.org/wiki/Nano_differential_scanning_fluorimetry?action=history). Licenza: Creative Commons Attribuzione-Condividi allo stesso modo 4.0 (CC BY-SA 4.0) — https://creativecommons.org/licenses/by-sa/4.0/. Il riuso richiede attribuzione e stessa licenza. Estratto dell'introduzione non modificato nel contenuto; revisione 1364957469, consultata il 2026-10-07T23:36:25.347Z tramite l'API ufficiale di Wikipedia. Impronta SHA-256 dell'estratto: 8b9a50c2dcfe2dacaf681da0e03d110ea834239be3007d7d8e8dc5d964068acb