Metraipolis › archive › dc_cee7b25aef26
Fixed-Time Voltage Regulation in Distribution Networks with Impedance Awareness — arXiv:2610.01449
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.01449
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T12:30:35.344Z
- SHA-256 of the archived text
c5cf09f1d7cabbf79da451ab544bc1fe8f228fdfc41f7c33273005f5dde27a1a- Stable URL of this page
https://metraipolis.com/documento/dc_cee7b25aef26
How to cite
Fixed-Time Voltage Regulation in Distribution Networks with Impedance Awareness — arXiv:2610.01449 — arXiv (en), https://arxiv.org/abs/2610.01449 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cee7b25aef26 (Metraipolis archive dc_cee7b25aef26, sha256 c5cf09f1d7cabbf79da451ab544bc1fe8f228fdfc41f7c33273005f5dde27a1a)
BibTeX
@misc{dccee7b25aef26,
title = {Fixed-Time Voltage Regulation in Distribution Networks with Impedance Awareness — arXiv:2610.01449},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.01449},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cee7b25aef26; sha256 c5cf09f1d7cabbf79da451ab544bc1fe8f228fdfc41f7c33273005f5dde27a1a},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.01449. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This letter introduces an optimization-based fixed time control algorithm for solving the voltage regulation problem of a radial and balanced power distribution network. The proposed algorithm requires no prior knowledge of the exact network impedance (resistance and reactance), yet guarantees voltage convergence to the predefined safe limit within a fixed time-window. We embrace results from Fixed-time stability (FxTs) and Control Lyapunov function (CLF) to analyze the stability and robustness of the underlying algorithm and then synthesize it leveraging the Quadratic Programming (QP) approach. We first analytically provide sufficient conditions on the control gains and the design parameters, that can ensure voltage regulation in fixed-time. Thereafter we transform the existing voltage regulation problem into an equivalent QP-based optimization framework and translate the aforesaid conditions to find feasible solutions for voltage stability. We empirically verify the efficacy of our proposed algorithm on the IEEE-33 bus distribution network and compare its performance against other existing robust control methods. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-10-02 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2610.01449 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T12:03:07.618Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-10-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).