Metraipolis › archive › dc_ce0e5c981190
Analytical Prediction of Equilibrium Existence in Current-Limited Grid-Forming Inverters — arXiv:2608.04740
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.04740
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T12:13:20.287Z
- SHA-256 of the archived text
ea1bf2c949ec08bcd444641388f28ef9031b475e4022c12942306ae9d895f35c- Stable URL of this page
https://metraipolis.com/documento/dc_ce0e5c981190
How to cite
Analytical Prediction of Equilibrium Existence in Current-Limited Grid-Forming Inverters — arXiv:2608.04740 — arXiv (en), https://arxiv.org/abs/2608.04740 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ce0e5c981190 (Metraipolis archive dc_ce0e5c981190, sha256 ea1bf2c949ec08bcd444641388f28ef9031b475e4022c12942306ae9d895f35c)
BibTeX
@misc{dcce0e5c981190,
title = {Analytical Prediction of Equilibrium Existence in Current-Limited Grid-Forming Inverters — arXiv:2608.04740},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.04740},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ce0e5c981190; sha256 ea1bf2c949ec08bcd444641388f28ef9031b475e4022c12942306ae9d895f35c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.04740. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
As converter-interfaced units become dominant in power systems, understanding nonlinear stability phenomena involving discrete switching events becomes essential for secure operation. The limited overcurrent capability of grid-forming (GFM) inverters makes current limiting essential during large disturbances. Activation of a circular current limiter (CCL) can cause the operating equilibrium to disappear under certain circumstances. This paper develops an analytical framework to predict the grid-voltage boundaries for CCL activation and determine whether the operating equilibrium persists or disappears after activation. For CCL-based GFM inverters with frozen anti-windup, closed-form expressions for the activation boundaries are derived while accounting for the filter capacitor. A criterion is established to determine whether a saturated (i.e., current-limited) stable equilibrium point (satSEP) persists following limiter activation. A continuation method is also developed to trace equilibria across normal-control and current-limited operation. Power-angle analysis and dynamic-model continuation in single-inverter and modified 9-bus systems validate these predictions. Time-domain simulations further confirm the results. The results show that CCL activation can either cause immediate loss of the stable equilibrium or allow stable current-limited operation to continue until the equilibrium is lost as operating conditions change further. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-06 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2608.04740 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T12:03:41.306Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-08-06?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).