Metraipolis › archive › dc_cdb16954ab12

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI — arXiv:2609.31777

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.31777
License (as archived)
CC0-1.0
Archived
2026-10-07T23:55:00.631Z
SHA-256 of the archived text
4441caae8b47c406ef2cf7c9d7979a4465acde1d140be888b33d1b70d8237646
Stable URL of this page
https://metraipolis.com/documento/dc_cdb16954ab12

How to cite

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI — arXiv:2609.31777 — arXiv (en), https://arxiv.org/abs/2609.31777 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cdb16954ab12 (Metraipolis archive dc_cdb16954ab12, sha256 4441caae8b47c406ef2cf7c9d7979a4465acde1d140be888b33d1b70d8237646)
BibTeX
@misc{dccdb16954ab12,
  title = {Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI — arXiv:2609.31777},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.31777},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cdb16954ab12; sha256 4441caae8b47c406ef2cf7c9d7979a4465acde1d140be888b33d1b70d8237646},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31777. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1\rho$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1\rho$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV).
Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.31777 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:29:27.649Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).