Metraipolis › archive › dc_cd6f366e6f79

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation… — arXiv:2609.29433

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.29433
License (as archived)
CC0-1.0
Archived
2026-10-08T04:27:30.354Z
SHA-256 of the archived text
633b24765108383ed2fd1792b18626529d50cc3eca56ca2adf9a8210d5301f04
Stable URL of this page
https://metraipolis.com/documento/dc_cd6f366e6f79

How to cite

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation… — arXiv:2609.29433 — arXiv (en), https://arxiv.org/abs/2609.29433 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cd6f366e6f79 (Metraipolis archive dc_cd6f366e6f79, sha256 633b24765108383ed2fd1792b18626529d50cc3eca56ca2adf9a8210d5301f04)
BibTeX
@misc{dccd6f366e6f79,
  title = {Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation… — arXiv:2609.29433},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.29433},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cd6f366e6f79; sha256 633b24765108383ed2fd1792b18626529d50cc3eca56ca2adf9a8210d5301f04},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.29433. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-25 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.29433 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T03:50:58.061Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).