Metraipolis › archive › dc_cc6f07df1fe9

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays — arXiv:2608.11288

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.11288
License (as archived)
CC0-1.0
Archived
2026-10-19T05:40:11.677Z
SHA-256 of the archived text
29f3803a87fba86a054c11a8a49e730666b4f74d831e817fdbf123415b0fb8e2
Stable URL of this page
https://metraipolis.com/documento/dc_cc6f07df1fe9

How to cite

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays — arXiv:2608.11288 — arXiv (en), https://arxiv.org/abs/2608.11288 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cc6f07df1fe9 (Metraipolis archive dc_cc6f07df1fe9, sha256 29f3803a87fba86a054c11a8a49e730666b4f74d831e817fdbf123415b0fb8e2)
BibTeX
@misc{dccc6f07df1fe9,
  title = {Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays — arXiv:2608.11288},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.11288},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cc6f07df1fe9; sha256 29f3803a87fba86a054c11a8a49e730666b4f74d831e817fdbf123415b0fb8e2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.11288. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Assessing catheter and tube placement on chest X-rays is safety-critical yet tedious and error-prone. Current deep learning methods either classify placement globally -- losing track of which device is where -- or segment all devices into a single mask, making per-device assessment impossible when catheters overlap. We introduce UCompCXR, a compositional framework that detects local catheter fragments, associates them into device instances via graph-based clustering, fuses per-fragment tip predictions through precision-weighted Gaussian estimation, and classifies placement per device. On the RANZCR CLiP dataset (30,083 images, 5-fold patient-level CV with bootstrap CIs), UCompCXR detects 26% more devices than a strong multi-task baseline sharing the same MobileNetV3 backbone, with 75% fewer false positives and well-calibrated tip uncertainty (95% coverage = 0.948). The aggregate tip error rises -- but only because the model finds devices the baseline misses entirely, especially nasogastric tubes. On matched devices, catastrophic localization failures drop substantially. At 2.27M parameters in a single forward pass, the model is deployable on resource-constrained clinical hardware.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-13 in cs.LG).
Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2608.11288 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T05:18:32.527Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-08-13?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).