Metraipolis › archive › dc_cc0aadf2820b

Factors influencing environmental sampling recovery of healthcare pathogens from non-porous surfaces with cellulose sponges — Europe PMC PMID:35025906

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/35025906
DOI
10.1371/journal.pone.0261588
License (as archived)
CC0-1.0
Archived
2026-10-31T15:04:53.271Z
SHA-256 of the archived text
fc780e00cbc27cc2c16e59ab77eecf0718bbba338aed9770204d31d3dcfa0799
Stable URL of this page
https://metraipolis.com/documento/dc_cc0aadf2820b

How to cite

Factors influencing environmental sampling recovery of healthcare pathogens from non-porous surfaces with cellulose sponges — Europe PMC PMID:35025906 — Europe PMC (en), https://europepmc.org/article/MED/35025906 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cc0aadf2820b (Metraipolis archive dc_cc0aadf2820b, sha256 fc780e00cbc27cc2c16e59ab77eecf0718bbba338aed9770204d31d3dcfa0799)
BibTeX
@misc{dccc0aadf2820b,
  title = {Factors influencing environmental sampling recovery of healthcare pathogens from non-porous surfaces with cellulose sponges — Europe PMC PMID:35025906},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/35025906},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cc0aadf2820b; sha256 fc780e00cbc27cc2c16e59ab77eecf0718bbba338aed9770204d31d3dcfa0799},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/35025906. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Results from sampling healthcare surfaces for pathogens are difficult to interpret without understanding the factors that influence pathogen detection. We investigated the recovery of four healthcare-associated pathogens from three common surface materials, and how a body fluid simulant (artificial test soil, ATS), deposition method, and contamination levels influence the percent of organisms recovered (%R). Known quantities of carbapenemase-producing KPC+ Klebsiella pneumoniae (KPC), Acinetobacter baumannii, vancomycin-resistant Enterococcus faecalis, and Clostridioides difficile spores (CD) were suspended in Butterfield's buffer or ATS, deposited on 323cm2 steel, plastic, and laminate surfaces, allowed to dry 1h, then sampled with a cellulose sponge wipe. Bacteria were eluted, cultured, CFU counted and %R determined relative to the inoculum. The %R varied by organism, from 1 log10 within the 60 min drying time. For all organisms, the %R was significantly greater if suspended in ATS than if suspended in Butterfield's buffer (p<0.05), and for most organisms the %R was not significantly different when sampled from any of the three surfaces. Organisms deposited in multiple droplets were recovered at equal or higher %R than if spread evenly on the surface. This work assists in interpreting data collected while investigating a healthcare infection outbreak or while conducting infection intervention studies.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2022 (prima pubblicazione 2022-01-13).
Identificativi: PMID 35025906 · PMCID PMC8757884 · DOI 10.1371/journal.pone.0261588.
Pagina: https://europepmc.org/article/MED/35025906 — https://doi.org/10.1371/journal.pone.0261588. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-31T14:56:32.211Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.