Metraipolis › archive › dc_cbd33febb891
VNS Tokamak for Medical Isotope Production — arXiv:2609.24371
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.24371
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T23:41:18.597Z
- SHA-256 of the archived text
9001068c48a2e2ab3ce896496ad486caae6227c157b022a6914c707e20573de4- Stable URL of this page
https://metraipolis.com/documento/dc_cbd33febb891
How to cite
VNS Tokamak for Medical Isotope Production — arXiv:2609.24371 — arXiv (en), https://arxiv.org/abs/2609.24371 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cbd33febb891 (Metraipolis archive dc_cbd33febb891, sha256 9001068c48a2e2ab3ce896496ad486caae6227c157b022a6914c707e20573de4)
BibTeX
@misc{dccbd33febb891,
title = {VNS Tokamak for Medical Isotope Production — arXiv:2609.24371},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.24371},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cbd33febb891; sha256 9001068c48a2e2ab3ce896496ad486caae6227c157b022a6914c707e20573de4},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.24371. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The Volumetric Neutron Source (VNS) tokamak is a proposed fusion reactor for testing components under fusion neutron irradiation, and has potential use for radioisotope production. The VNS geometry is modeled in the Serpent 2.2.2 and OpenMC 0.15.2 neutronics codes. Coupled neutron-photon simulations compared fluxes, spectra, and selected reaction rates in the blanket and vacuum vessel. Good agreement was found overall, with the largest difference found in (n, 2n) reactions. On an HPC cluster, Serpent 2 was found to have shorter computation time in coupled simulations, while OpenMC was faster in neutron only simulations. Radioisotope production yields were simulated in Serpent 2.2.2 for capsule and Cobalt plate irradiation facilities. Results indicate potential for large volume production of 99Mo, 131I, 225Ac, 177Lu, 192Ir, 64Cu, 67Cu, 161Tb, and 153Sm while 203Pb indicates lower potential. 100Mo and LEU target heating was calculated, suggesting the LEU target mass or the cooling may need adjustment. Optimized 60Co production yielded 1.2 GBq/mg and 100,000 TBq after a 3-year irradiation period. Sensitivity to plant outage for 99Mo, 131I, 177Lu, and 60Co was simulated, suggesting irradiation can be restarted for the same isotope loading and demonstrated long-lived 60Co to be robust to long plant dwell-time. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-22 in physics.comp-ph). Categorie arXiv: Computational Physics (physics.comp-ph) ; Applied Physics (physics.app-ph). Pagina del lavoro: https://arxiv.org/abs/2609.24371 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T22:46:47.364Z dalla pagina https://arxiv.org/catchup/physics.comp-ph/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).