Metraipolis › archive › dc_cbc552c10846
An Event-Driven Cloud-Native Wearable Analytics Framework for Real-Time Clinical Workloads — arXiv:2608.11402
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.11402
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T05:31:04.243Z
- SHA-256 of the archived text
cc3f46e28154219853063ff396b81b92aa38b1214157daf1e263b2e88a22c184- Stable URL of this page
https://metraipolis.com/documento/dc_cbc552c10846
How to cite
An Event-Driven Cloud-Native Wearable Analytics Framework for Real-Time Clinical Workloads — arXiv:2608.11402 — arXiv (en), https://arxiv.org/abs/2608.11402 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cbc552c10846 (Metraipolis archive dc_cbc552c10846, sha256 cc3f46e28154219853063ff396b81b92aa38b1214157daf1e263b2e88a22c184)
BibTeX
@misc{dccbc552c10846,
title = {An Event-Driven Cloud-Native Wearable Analytics Framework for Real-Time Clinical Workloads — arXiv:2608.11402},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.11402},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cbc552c10846; sha256 cc3f46e28154219853063ff396b81b92aa38b1214157daf1e263b2e88a22c184},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.11402. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Continuous physiological monitoring using consumer-grade wearables offers a transformative opportunity for clinical care and research, yet integration remains hindered by device heterogeneity, proprietary data formats, and strict regulatory requirements. We present an event-driven, cloud-native system designed to ingest, normalize, and analyze high-frequency vital signs from wearables at scale and without vendor lock-in. The system design proposes a multi-layered microservice architecture using cluster orchestration. Data acquisition is handled via a cross-platform mobile application that leverages native health frameworks, ensuring compatibility across fragmented device ecosystems. To address interoperability, we implement an event-driven transformation pipeline using stream processing engines and specialized services to map raw measurements to the FHIR standard for medical interoperability. Our novel dependency-aware FHIR minimization scheme reduces storage overhead while maintaining lossless resource reconstruction. Furthermore, the platform integrates a modular data analytics and machine learning layer based on a medallion lakehouse architecture, supporting the full machine learning lifecycle from real-time stream processing to model serving. Performance evaluation demonstrates that the ingestion pipeline sustains 50 full ingestion requests per second with median response times under 8 ms, satisfying the low-latency requirements for real-time patient monitoring. Our open-source implementation adheres to regulatory compliance standards through role-based access control and secure service-to-service communication, providing a robust foundation for deploying wearable-based monitoring in institutional healthcare settings for clinical decision support and research workloads. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-13 in cs.DC). Categorie arXiv: Distributed, Parallel, and Cluster Computing (cs.DC). Pagina del lavoro: https://arxiv.org/abs/2608.11402 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T05:15:56.855Z dalla pagina https://arxiv.org/catchup/cs.DC/2026-08-13?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).