Metraipolis › archive › dc_cb96498d19fd

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model — arXiv:2610.20462

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.20462
License (as archived)
CC0-1.0
Archived
2026-10-15T14:20:32.565Z
SHA-256 of the archived text
3bb28d55bae4fa7d6b1e3ca2b5181654bdffaeec47e30a032d97c60dff257065
Stable URL of this page
https://metraipolis.com/documento/dc_cb96498d19fd

How to cite

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model — arXiv:2610.20462 — arXiv (en), https://arxiv.org/abs/2610.20462 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cb96498d19fd (Metraipolis archive dc_cb96498d19fd, sha256 3bb28d55bae4fa7d6b1e3ca2b5181654bdffaeec47e30a032d97c60dff257065)
BibTeX
@misc{dccb96498d19fd,
  title = {Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model — arXiv:2610.20462},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.20462},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cb96498d19fd; sha256 3bb28d55bae4fa7d6b1e3ca2b5181654bdffaeec47e30a032d97c60dff257065},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.20462. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Foundation models have shown strong generalization across scientific domains, but their use in power systems remains largely task-specific. We investigate whether a pretrained tabular foundation model (TFM), TabPFN, can serve as a general-purpose neural solver for power grid steady-state analysis. We evaluate the TFM on three tasks: power flow (PF) prediction, N-k contingency screening (NCS), and voltage stability margin (VSM) prediction. We performed experiments on 118- and 2000-bus systems, comparing the TFM against task-specific neural baselines. Without retraining or fine-tuning, the TFM matches or outperforms the best task-specific model in several settings across the three tasks. For 118-bus PF prediction, a variant of the TFM achieves errors of $1\times 10^{-3}$ pu for voltage magnitudes and $0.30^\circ$ for voltage angles, outperforming all baselines. On unseen N-1 contingency and close-to-infeasible PF cases, the TFM is competitive with the DCPF approximation. For millions of unseen N-2 contingencies, the TFM achieves AUCs of 0.92 and 0.95 for branch and voltage violation screening, respectively. The TFM also attains accurate VSM prediction performance for the 2000-bus system with limited labelled data. The TFM attains strong results across the tested tasks despite pretraining without any power-system-specific dataset and requiring no fine-tuning step. These results offer a glimpse into the potential of pretrained TFMs as a neural solver for a range of power grid analysis tasks.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2610.20462 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T13:53:35.756Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).