Metraipolis › archive › dc_cb5ab87fcdae
Optomechanical inertial reference for atom interferometry — arXiv:2608.28418
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28418
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T11:58:26.531Z
- SHA-256 of the archived text
c460bcbd97a25296b1eddd1a87225f4d62b0ac37975b71d7606bf54f07a0decf- Stable URL of this page
https://metraipolis.com/documento/dc_cb5ab87fcdae
How to cite
Optomechanical inertial reference for atom interferometry — arXiv:2608.28418 — arXiv (en), https://arxiv.org/abs/2608.28418 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cb5ab87fcdae (Metraipolis archive dc_cb5ab87fcdae, sha256 c460bcbd97a25296b1eddd1a87225f4d62b0ac37975b71d7606bf54f07a0decf)
BibTeX
@misc{dccb5ab87fcdae,
title = {Optomechanical inertial reference for atom interferometry — arXiv:2608.28418},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28418},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cb5ab87fcdae; sha256 c460bcbd97a25296b1eddd1a87225f4d62b0ac37975b71d7606bf54f07a0decf},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28418. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Atom interferometers are among the most sensitive inertial sensors, yet deployment outside the laboratory is limited by vibration noise, conventionally mitigated by external sensors or bulky isolation. Here we demonstrate a hybrid inertial sensor which fuses an optomechanical resonator and an atom interferometer by exploiting the resonator's test mass as the interferometer's reference mirror. This allows for better correlation than with two separate sensors, whose unknown transfer function is replaced by the static response of one mechanical element. The resonator achieves a displacement sensitivity of $8.6\cdot 10^{-15}$ m/$\sqrt{\mathrm{Hz}}$ with suppressed 1/f noise and yields a minimum acceleration sensitivity of $1.1\cdot10^{-6}$ m/s$^2$/$\sqrt{\mathrm{Hz}}$ over a bandwidth extending from sub-Hertz to 2.5 kHz. Under ambient laboratory conditions the integrated system removes vibration-induced phase ambiguity for accelerations up to $50\cdot 10^{-3}$ m/s$^2$ and reaches the interferometer's technical noise limit, which a commercial force-balance accelerometer does not. Because the resonance-tracking readout is largely independent of the mechanical design, the architecture transfers directly to other precision sensing platforms.
Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-31 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph) ; Atomic Physics (physics.atom-ph); Optics (physics.optics).
Pagina del lavoro: https://arxiv.org/abs/2608.28418 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T11:28:37.520Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-08-31?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).