Metraipolis › archive › dc_cb25c7a7d00e

SHIFT-M3: Pre-fusion Alignment-based Consistency Screening for Multimodal ECG Record Integrity — arXiv:2609.13874

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.13874
License (as archived)
CC0-1.0
Archived
2026-10-15T23:14:48.160Z
SHA-256 of the archived text
0c1e8c9660004a08f33f8d488e0b6432a8421cb89250114d361aef6ebd89b4cd
Stable URL of this page
https://metraipolis.com/documento/dc_cb25c7a7d00e

How to cite

SHIFT-M3: Pre-fusion Alignment-based Consistency Screening for Multimodal ECG Record Integrity — arXiv:2609.13874 — arXiv (en), https://arxiv.org/abs/2609.13874 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cb25c7a7d00e (Metraipolis archive dc_cb25c7a7d00e, sha256 0c1e8c9660004a08f33f8d488e0b6432a8421cb89250114d361aef6ebd89b4cd)
BibTeX
@misc{dccb25c7a7d00e,
  title = {SHIFT-M3: Pre-fusion Alignment-based Consistency Screening for Multimodal ECG Record Integrity — arXiv:2609.13874},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.13874},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cb25c7a7d00e; sha256 0c1e8c9660004a08f33f8d488e0b6432a8421cb89250114d361aef6ebd89b4cd},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.13874. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Multimodal clinical AI typically assumes that the waveform, report, metadata, and downstream predictions attached to a record belong to the same patient. In practice, linkage failures can silently assemble individually plausible but cross-patient components, creating a safety problem that standard predictive models are not designed to detect. We study this problem as multimodal record integrity triage: given an assembled record, should its modalities be trusted to belong together? We introduce SHIFT-M3, a lightweight text-based pre-fusion screen that measures alignment-based consistency between two separately produced ECG text views: an LLM-generated interpretation and a clinical report summary. On 784,680 MEETI ECG records, SHIFT-M3 achieves 97.6% TPR@5% FPR for full text-view swaps (AUROC 0.996), 90.3% for partial swaps (AUROC 0.974), and 97.7% for label-matched hard negatives (AUROC 0.996) with only 573,569 parameters. Compared with same-dataset lexical baselines, the gains are largest on partial swaps and hard negatives, suggesting that the model is learning more than surface overlap. We also introduce the CMST (Conflict-type Multimodal Stress Test) evaluation taxonomy, a three-seed stability study, a loss ablation, a temporal-tolerance sweep, and a shared-token masking control. The main remaining failure mode is longitudinal ambiguity: at the default operating point, same-patient cross-visit pairs still produce 87.0% Type-II false positives.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.CL).
Categorie arXiv: Computation and Language (cs.CL).
Pagina del lavoro: https://arxiv.org/abs/2609.13874 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T22:51:09.849Z dalla pagina https://arxiv.org/catchup/cs.CL/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).