Metraipolis › archive › dc_cb18f0f5d81a

Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty Analysis — arXiv:2608.30835

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.30835
License (as archived)
CC0-1.0
Archived
2026-10-17T07:55:01.214Z
SHA-256 of the archived text
b7aa4aaadd2a20fb379fe4f2fb0039d12f0a9c126119bfeedf8846bb3d3e9d4e
Stable URL of this page
https://metraipolis.com/documento/dc_cb18f0f5d81a

How to cite

Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty Analysis — arXiv:2608.30835 — arXiv (en), https://arxiv.org/abs/2608.30835 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_cb18f0f5d81a (Metraipolis archive dc_cb18f0f5d81a, sha256 b7aa4aaadd2a20fb379fe4f2fb0039d12f0a9c126119bfeedf8846bb3d3e9d4e)
BibTeX
@misc{dccb18f0f5d81a,
  title = {Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty Analysis — arXiv:2608.30835},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.30835},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_cb18f0f5d81a; sha256 b7aa4aaadd2a20fb379fe4f2fb0039d12f0a9c126119bfeedf8846bb3d3e9d4e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.30835. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are compared share four properties that make their reported differences hard to interpret: few independent slides, annotation concentrated in a minority of them, pooled ratio metrics with no closed-form standard error, and a single inherited train/test partition. We propose a reliability protocol for such benchmarks. Methods: The protocol quantifies four sources of variability - test-set sampling, training stochasticity, partition composition, and undocumented preprocessing - a claim is reportable only if it survives all four; three of the four cost minutes of compute. We apply it to an independent reconstruction of a published diffusion-based artifact detector, evaluated on the original 24-slide partition and against a supervised baseline. Results: The method's central mechanism reproduces: the auxiliary contrastive term improves pooled F1 from 0.673 to 0.688 and replicates under a second seed (+0.0156, p = 0.031; +0.0190, p = 0.005), although it acts on pen marking rather than the artifact types cited to motivate it. Its comparative claims do not: differences between design variants, and against the supervised baseline, fall inside the uncertainty of the evaluation. Four of 24 slides carry 70% of scored annotated pixels, giving an effective sample size of 6.2, and the inherited partition sits at the 7th percentile. An unreported tissue-restriction step excludes 41.4% of out-of-focus annotation against 2.6% of air bubble; such a gate is confounded with blur by construction. Conclusions: Small-cohort benchmarks support far weaker conclusions than current reporting implies. The four checks are cheap enough to accompany any evaluation on such a resource and separate reproducible effects from differences the evaluation cannot resolve.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.30835 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T07:28:26.913Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).