Metraipolis › archive › dc_ca51465a9100
Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU — arXiv:2609.08992
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.08992
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T13:58:27.191Z
- SHA-256 of the archived text
0903a4890e6a70c5e12ad16fb380fe66fe58913fe192c777c815ef6b7e2d51f0- Stable URL of this page
https://metraipolis.com/documento/dc_ca51465a9100
How to cite
Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU — arXiv:2609.08992 — arXiv (en), https://arxiv.org/abs/2609.08992 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ca51465a9100 (Metraipolis archive dc_ca51465a9100, sha256 0903a4890e6a70c5e12ad16fb380fe66fe58913fe192c777c815ef6b7e2d51f0)
BibTeX
@misc{dcca51465a9100,
title = {Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU — arXiv:2609.08992},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.08992},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ca51465a9100; sha256 0903a4890e6a70c5e12ad16fb380fe66fe58913fe192c777c815ef6b7e2d51f0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.08992. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-09 in cs.LG). Categorie arXiv: Machine Learning (cs.LG) ; Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2609.08992 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T13:39:43.080Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).