Metraipolis › archive › dc_ca41125cd9e8

Human Activity Recognition using Ceiling-Mounted Multi-Radar Sensors — arXiv:2610.39628

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.39628
License (as archived)
CC0-1.0
Archived
2026-11-01T03:01:03.610Z
SHA-256 of the archived text
f8571db6c4f4e83917c320352ebae592d530eefab5924b3e5913ad8d7675d748
Stable URL of this page
https://metraipolis.com/documento/dc_ca41125cd9e8

How to cite

Human Activity Recognition using Ceiling-Mounted Multi-Radar Sensors — arXiv:2610.39628 — arXiv (en), https://arxiv.org/abs/2610.39628 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ca41125cd9e8 (Metraipolis archive dc_ca41125cd9e8, sha256 f8571db6c4f4e83917c320352ebae592d530eefab5924b3e5913ad8d7675d748)
BibTeX
@misc{dcca41125cd9e8,
  title = {Human Activity Recognition using Ceiling-Mounted Multi-Radar Sensors — arXiv:2610.39628},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.39628},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ca41125cd9e8; sha256 f8571db6c4f4e83917c320352ebae592d530eefab5924b3e5913ad8d7675d748},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39628. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Continuous activity monitoring in assisted living should work without cameras or wearable devices. Radar meets this requirement, but most radar studies use a single sensor and activities recorded in isolation, and few deliver results in real time. We present an indoor monitoring system in which point clouds from three ceiling-mounted radar sensors are fused using density-based clustering, movement and posture features are derived for activity classification, and results are shown on a real-time dashboard. In a preliminary study with eight participants performing everyday activities as one continuous scenario, a random forest reached 74% frame-level accuracy with a random 80/20 split and 68% with leave-one-participant-out evaluation. Without position features, accuracy fell to 46% and 44%, indicating partial dependence on room layout, while window-level features without position reached 67% and 65%.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.SP, nuovi lavori del giorno).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2610.39628 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:25:45.622Z dalla pagina https://arxiv.org/list/eess.SP/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).