Metraipolis › archive › dc_c9e73f003771

Short-Circuit Current Calculation in DC Shipboard Microgrid Using Operational Admittances — arXiv:2611.00262

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.00262
License (as archived)
CC0-1.0
Archived
2026-11-03T19:07:21.692Z
SHA-256 of the archived text
672b90104d0f5de1a9aa836419b10e7505cfcec71750e85f4e3a4d5c09f13aa6
Stable URL of this page
https://metraipolis.com/documento/dc_c9e73f003771

How to cite

Short-Circuit Current Calculation in DC Shipboard Microgrid Using Operational Admittances — arXiv:2611.00262 — arXiv (en), https://arxiv.org/abs/2611.00262 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c9e73f003771 (Metraipolis archive dc_c9e73f003771, sha256 672b90104d0f5de1a9aa836419b10e7505cfcec71750e85f4e3a4d5c09f13aa6)
BibTeX
@misc{dcc9e73f003771,
  title = {Short-Circuit Current Calculation in DC Shipboard Microgrid Using Operational Admittances — arXiv:2611.00262},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.00262},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c9e73f003771; sha256 672b90104d0f5de1a9aa836419b10e7505cfcec71750e85f4e3a4d5c09f13aa6},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00262. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The increasing adoption of DC shipboard power systems is driven by the need to integrate energy storage systems seamlessly onboard. In this context, accurate calculation of short-circuit current transients is critical for sizing fast-acting protection devices. This paper proposes a methodology to calculate short-circuit current transients based on operational admittance modelling of network elements and power converters. The superposition principle is then applied to calculate current contributions and voltage time profiles. The methodology is validated with a detailed EMT model of a notional LVDC shipboard microgrid section consisting of an active front end, a bidirectional buck-boost converter and two special loads. Results demonstrate that the methodology accurately tracks nodal voltages and the fault current contributions dynamics up to the prospective fault current peak, thus providing a computationally efficient tool for fault analysis and protection coordination in LVDC microgrids.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2611.00262 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T18:25:37.808Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).