Metraipolis › archive › dc_c9859e1b0299

Microkelvin resolution thermometry at the nanometre scale — arXiv:2609.04907

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.04907
License (as archived)
CC0-1.0
Archived
2026-10-17T00:01:38.159Z
SHA-256 of the archived text
4d7923772c6d4474c8a3eb232e9f31d4869619b7d20bd676eb52d295cd483a87
Stable URL of this page
https://metraipolis.com/documento/dc_c9859e1b0299

How to cite

Microkelvin resolution thermometry at the nanometre scale — arXiv:2609.04907 — arXiv (en), https://arxiv.org/abs/2609.04907 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c9859e1b0299 (Metraipolis archive dc_c9859e1b0299, sha256 4d7923772c6d4474c8a3eb232e9f31d4869619b7d20bd676eb52d295cd483a87)
BibTeX
@misc{dcc9859e1b0299,
  title = {Microkelvin resolution thermometry at the nanometre scale — arXiv:2609.04907},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.04907},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c9859e1b0299; sha256 4d7923772c6d4474c8a3eb232e9f31d4869619b7d20bd676eb52d295cd483a87},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04907. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 $\mu$K, experimental sensitivities below 50 mK/$\surd \text{Hz}$ and a shot-noise limited sensitivity of 9.6 mK/$\surd \text{Hz}$. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-07 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph) ; Applied Physics (physics.app-ph); Instrumentation and Detectors (physics.ins-det).