Metraipolis › archive › dc_c813a30691ae
Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening — arXiv:2609.22281
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.22281
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T21:59:05.274Z
- SHA-256 of the archived text
d782eb8b5261292fab63a2740a01325aaf15d1aae37f92f93e659e4a7bd4acac- Stable URL of this page
https://metraipolis.com/documento/dc_c813a30691ae
How to cite
Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening — arXiv:2609.22281 — arXiv (en), https://arxiv.org/abs/2609.22281 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c813a30691ae (Metraipolis archive dc_c813a30691ae, sha256 d782eb8b5261292fab63a2740a01325aaf15d1aae37f92f93e659e4a7bd4acac)
BibTeX
@misc{dcc813a30691ae,
title = {Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening — arXiv:2609.22281},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.22281},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c813a30691ae; sha256 d782eb8b5261292fab63a2740a01325aaf15d1aae37f92f93e659e4a7bd4acac},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.22281. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Foundation models have recently demonstrated strong capabilities across a wide range of medical imaging tasks. However, their performance in structured clinical interpretation settings remains insufficiently explored. In lung cancer screening, interpretative variability persists despite standardized frameworks such as Lung-RADS. In this study, we evaluate MedGemma, a medical general-purpose foundation model derived from Gemini and its fine-tuned version adapted for lung cancer detection and diagnosis, compared against radiologists performing Lung-RADS v2022 assessment on the NLST dataset. Twelve radiologists independently evaluated each case in a multi-reader design, enabling quantification of inter-reader variability. Radiologists achieved a mean AUC of 0.90, with substantial variability across readers (range: 0.80-0.94). The native foundation model achieved an AUC of 0.70, failing to reach clinically relevant performance. In contrast, fine-tuning significantly improved performance to an AUC of 0.83, placing the model within the lower range of individual radiologists performance. These findings highlight a trade-off between peak accuracy and prediction consistency. Unlike radiologists, under fixed conditions, the model produces deterministic outputs, removing inter-run variability under identical inputs, in contrast to inter-reader variability observed among radiologists. This supports the role of fine-tuned foundation models potential complementary tools for clinical decision support, particularly in settings with limited expertise. However, evaluation is performed on a case-enriched cohort from NLST and does not account for real-world prevalence or external validation, limiting direct clinical generalization. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2609.22281 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T21:45:20.771Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).