Metraipolis › archive › dc_c7f00c533c73
PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI — arXiv:2609.30431
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.30431
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T04:19:42.687Z
- SHA-256 of the archived text
a4a1e2700725b8fbbd50a548484600b5a89026038587895bb179c266deaf58e8- Stable URL of this page
https://metraipolis.com/documento/dc_c7f00c533c73
How to cite
PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI — arXiv:2609.30431 — arXiv (en), https://arxiv.org/abs/2609.30431 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c7f00c533c73 (Metraipolis archive dc_c7f00c533c73, sha256 a4a1e2700725b8fbbd50a548484600b5a89026038587895bb179c266deaf58e8)
BibTeX
@misc{dcc7f00c533c73,
title = {PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI — arXiv:2609.30431},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.30431},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c7f00c533c73; sha256 a4a1e2700725b8fbbd50a548484600b5a89026038587895bb179c266deaf58e8},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.30431. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Magnetic Resonance Imaging (MRI) often suffers from low signal-to-noise ratio (SNR) and limited spatial resolution, which compromise clinical precision. This study aims to address these challenges by developing a physics-guided degradation model (PGDM) and a novel deep learning framework, Magnetic Resonance Super-Resolution GAN Imaging (MRSRGAN), for improved super-resolution reconstruction of MRI images. The proposed approach consists of two stages: (1) a physics-guided degradation model that simulates low-field MRI conditions by incorporating artifacts such as blur, B0 inhomogeneity, chemical shift effects, down-sampling, and noise to generate paired low-resolution (LR) and high-resolution (HR) training datasets; and (2) an MRSRGAN-based reconstruction network utilizing a hybrid loss function, including modified spectral angle mapper (MSAM) and sharpened ground truth images based on de-convolution of slice profile-based kernels to restore high-SNR and high-resolution images. Experimental validation demonstrates that the proposed method achieves superior spatial resolution, enhanced SNR, improved peak signal-to-noise ratio (PSNR), higher structural similarity index (SSIM), reduced MSAM error, and better non-reference image quality evaluation (NIQE) metrics. Furthermore, it effectively reduces artifacts and demonstrates robustness on real MRI datasets. The MRSRGAN framework, guided by the physics-informed degradation model, provides a significant improvement in MRI image quality, enhancing spatial resolution and diagnostic accuracy. Its demonstrated robustness and effectiveness on real MRI datasets highlight its potential to resolution enhancement for precise diagnostic imaging. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-28 in eess.IV). Categorie arXiv: Image and Video Processing (eess.IV) ; Medical Physics (physics.med-ph). Pagina del lavoro: https://arxiv.org/abs/2609.30431 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T03:50:20.757Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-09-28?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).