Metraipolis › archive › dc_c6dc1f57c9da

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment — arXiv:2611.05741

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.05741
License (as archived)
CC0-1.0
Archived
2026-11-05T18:30:33.663Z
SHA-256 of the archived text
41438bbc21d690faa62acf7499da650b9a2632245e64e0fc50c522404935fc1e
Stable URL of this page
https://metraipolis.com/documento/dc_c6dc1f57c9da

How to cite

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment — arXiv:2611.05741 — arXiv (en), https://arxiv.org/abs/2611.05741 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c6dc1f57c9da (Metraipolis archive dc_c6dc1f57c9da, sha256 41438bbc21d690faa62acf7499da650b9a2632245e64e0fc50c522404935fc1e)
BibTeX
@misc{dcc6dc1f57c9da,
  title = {OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment — arXiv:2611.05741},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.05741},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c6dc1f57c9da; sha256 41438bbc21d690faa62acf7499da650b9a2632245e64e0fc50c522404935fc1e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05741. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2611.05741 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-05T18:20:03.981Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).