Metraipolis › archive › dc_c3f3bc457e94

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation — arXiv:2608.10401

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.10401
License (as archived)
CC0-1.0
Archived
2026-10-19T06:18:45.397Z
SHA-256 of the archived text
4d4192cba6d93e1447ae429b9768decc666ec77817e520d1f7a84f485f742b58
Stable URL of this page
https://metraipolis.com/documento/dc_c3f3bc457e94

How to cite

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation — arXiv:2608.10401 — arXiv (en), https://arxiv.org/abs/2608.10401 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c3f3bc457e94 (Metraipolis archive dc_c3f3bc457e94, sha256 4d4192cba6d93e1447ae429b9768decc666ec77817e520d1f7a84f485f742b58)
BibTeX
@misc{dcc3f3bc457e94,
  title = {Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation — arXiv:2608.10401},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.10401},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c3f3bc457e94; sha256 4d4192cba6d93e1447ae429b9768decc666ec77817e520d1f7a84f485f742b58},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.10401. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-12 in cs.HC).
Categorie arXiv: Human-Computer Interaction (cs.HC) ; Machine Learning (cs.LG); Robotics (cs.RO); Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2608.10401 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T06:11:23.447Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-08-12?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).