Metraipolis › archive › dc_c31a6609382b

Source--Grid Coupling in Power System Oscillations: Observational Equivalence, Feedback Detectability, and Modal Interaction — arXiv:2609.20943

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.20943
License (as archived)
CC0-1.0
Archived
2026-10-10T03:11:52.180Z
SHA-256 of the archived text
aa2bd1826339165e377f27e286c63034dc925c583e95f7f8eb1d2f029fc2830c
Stable URL of this page
https://metraipolis.com/documento/dc_c31a6609382b

How to cite

Source--Grid Coupling in Power System Oscillations: Observational Equivalence, Feedback Detectability, and Modal Interaction — arXiv:2609.20943 — arXiv (en), https://arxiv.org/abs/2609.20943 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c31a6609382b (Metraipolis archive dc_c31a6609382b, sha256 aa2bd1826339165e377f27e286c63034dc925c583e95f7f8eb1d2f029fc2830c)
BibTeX
@misc{dcc31a6609382b,
  title = {Source--Grid Coupling in Power System Oscillations: Observational Equivalence, Feedback Detectability, and Modal Interaction — arXiv:2609.20943},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.20943},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c31a6609382b; sha256 aa2bd1826339165e377f27e286c63034dc925c583e95f7f8eb1d2f029fc2830c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.20943. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The conventional distinction between forced and natural oscillations treats the oscillation source as external to a fixed power-system boundary. This paper develops a coupling-aware dynamical interpretation by explicitly accounting for the directionality of source-grid coupling. It examines when prescribed forcing and a one-way autonomous source are observationally equivalent, and when grid measurements can distinguish the presence of grid-to-source feedback. Matched interface signals yield exact equivalence under the same deterministic grid initial-value problem and measurement map. Bidirectional feedback enables source-grid eigenvalue interaction in the augmented autonomous model, while a reduced two-mode model shows that the interaction depends jointly on loop coupling and complex modal separation. The resulting framework establishes source-grid coupling directionality as a feedback-based dynamical boundary and clarifies when feedback can be inferred from grid-side measurements and why weak feedback may remain unresolved. Simulation studies on a two-area system demonstrate feedback detection within a calibrated source family, while source-model mismatch can be confounded with feedback. A WECC 243-bus system study demonstrates feasibility on a large system and shows that feedback detection need not require exact candidate selection.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-21 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY) ; Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2609.20943 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-10T02:58:16.884Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).