Metraipolis › archive › dc_c28e33b2c52a
One Agent per Zone: Decentralised Active Inference under Partial Observability for Multi-Zone HVAC Control on Edge Hardware — arXiv:2610.19790
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19790
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T13:50:39.544Z
- SHA-256 of the archived text
3b0a7e70405745a814cb61497cd6b8f3fef6501e38cc7b68df8ed350bbf953e8- Stable URL of this page
https://metraipolis.com/documento/dc_c28e33b2c52a
How to cite
One Agent per Zone: Decentralised Active Inference under Partial Observability for Multi-Zone HVAC Control on Edge Hardware — arXiv:2610.19790 — arXiv (en), https://arxiv.org/abs/2610.19790 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c28e33b2c52a (Metraipolis archive dc_c28e33b2c52a, sha256 3b0a7e70405745a814cb61497cd6b8f3fef6501e38cc7b68df8ed350bbf953e8)
BibTeX
@misc{dcc28e33b2c52a,
title = {One Agent per Zone: Decentralised Active Inference under Partial Observability for Multi-Zone HVAC Control on Edge Hardware — arXiv:2610.19790},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19790},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c28e33b2c52a; sha256 3b0a7e70405745a814cb61497cd6b8f3fef6501e38cc7b68df8ed350bbf953e8},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19790. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Multi-zone HVAC control is a shared-resource problem: zones on a floor share one fan and cooling coil, so each zone's demand affects its neighbours and the building's peak power. One controller per zone scales well and isolates faults, but each controller then observes only its own zone, not the shared air loop. In this work, we present a decentralised controller that assigns each zone an independent active-inference agent, which plans by minimising expected free energy and learns its zone dynamics online. The agents exchange no messages, so none depends on peers or a coordinator; each accounts for the unobserved coupling through a latent disturbance and a congestion signal derived from the metered power of the other floors. Fifteen agents are evaluated in EnergyPlus on a Sinergym office building against three rule-based controllers and three MADDPG fleets, one given the same floor meters. On five noisy weather years unseen during training, the fleet attains the lowest mean building peak (88.3 kW, 3 to 17 % below the baselines) and staggers the floor peaks better than any baseline, with a coincidence factor (building peak over the sum of the floor peaks) of 0.929 versus 0.936 to 0.994. Compared with a reactive rule at similar comfort (0.912 versus 0.916), it lowers the sum of monthly peaks, on which demand charges are billed, by 33 kW (4 %) in every year, at the cost of about 10 % more energy. It costs 9% less per year than the proactive rule (at lower comfort) and 1% less than the MADDPG fleet given the same floor meters, in every test year. The whole fleet runs on a single low-cost Raspberry Pi 5, closing the observation-to-action loop over MQTT in 442 ms at p95, far below the 15-minute control step. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.MA, nuovi lavori del giorno). Categorie arXiv: Multiagent Systems (cs.MA) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.19790 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T13:48:35.438Z dalla pagina https://arxiv.org/list/cs.MA/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).