Metraipolis › archive › dc_c24936e37985

Optimal Day-Ahead Scheduling of Fast EV Charging Station With Multi-Stage Battery Degradation Model — arXiv:2609.20946

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.20946
License (as archived)
CC0-1.0
Archived
2026-10-10T03:11:52.837Z
SHA-256 of the archived text
45c9a53fc90480c9ec0506a795eef81a4ddfe211699a3b5ba99a49848cb8da95
Stable URL of this page
https://metraipolis.com/documento/dc_c24936e37985

How to cite

Optimal Day-Ahead Scheduling of Fast EV Charging Station With Multi-Stage Battery Degradation Model — arXiv:2609.20946 — arXiv (en), https://arxiv.org/abs/2609.20946 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c24936e37985 (Metraipolis archive dc_c24936e37985, sha256 45c9a53fc90480c9ec0506a795eef81a4ddfe211699a3b5ba99a49848cb8da95)
BibTeX
@misc{dcc24936e37985,
  title = {Optimal Day-Ahead Scheduling of Fast EV Charging Station With Multi-Stage Battery Degradation Model — arXiv:2609.20946},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.20946},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c24936e37985; sha256 45c9a53fc90480c9ec0506a795eef81a4ddfe211699a3b5ba99a49848cb8da95},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.20946. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The paper proposes a day-ahead scheduling framework with a novel multi-stage battery degradation modeling method for an electric vehicle (EV) fast charging station (FCS) equipped with a battery energy storage system (BESS). Unlike previous studies, which employ a single battery degradation model to represent the aging process, this paper proposes a novel multi-stage battery degradation modeling method to accurately capture the degradation process across the whole lifespan. Subsequently, the multi-stage model is explicitly integrated into the proposed adaptive optimization framework in a computationally tractable way, thus having important practical implications in the field. The paper provides case studies to demonstrate the effectiveness of the proposed modeling method on a selected cycle aging model in reducing the operation cost of FCS with BESS operating in different stages. As a result, the overall operation cost with the multi-stage model is around 2.1% on average lower than the single-stage model counterpart. In addition, results show that with the increasing number of divided stages, the model error decreases and becomes stable, while the reduced operation cost compared with the single-stage model increases and saturates. Finally, we apply the multi-stage framework considering other conventional degradation models to show the superiority of the proposed method.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-21 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.20946 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-10T02:58:16.886Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).