Metraipolis › archive › dc_c1cec4805cb0

Lesion Overlap Ranks PET Segmentation Models but Does Not Certify Patient-Level Tumor Burden — arXiv:2611.05564

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.05564
License (as archived)
CC0-1.0
Archived
2026-11-05T18:29:40.182Z
SHA-256 of the archived text
f88a95c51066f8a6b042d54549753c3b8314ef1285cb5cb0d32474da978b0fd1
Stable URL of this page
https://metraipolis.com/documento/dc_c1cec4805cb0

How to cite

Lesion Overlap Ranks PET Segmentation Models but Does Not Certify Patient-Level Tumor Burden — arXiv:2611.05564 — arXiv (en), https://arxiv.org/abs/2611.05564 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c1cec4805cb0 (Metraipolis archive dc_c1cec4805cb0, sha256 f88a95c51066f8a6b042d54549753c3b8314ef1285cb5cb0d32474da978b0fd1)
BibTeX
@misc{dcc1cec4805cb0,
  title = {Lesion Overlap Ranks PET Segmentation Models but Does Not Certify Patient-Level Tumor Burden — arXiv:2611.05564},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.05564},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c1cec4805cb0; sha256 f88a95c51066f8a6b042d54549753c3b8314ef1285cb5cb0d32474da978b0fd1},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05564. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Metabolic tumor volume (MTV) summarizes whole-body PET disease burden for prognostic stratification and treatment assessment. Automated MTV is useful only if its estimate is reliable for the individual patient, yet segmentation models are usually evaluated with overlap metrics such as Dice rather than burden error. We examined whether overlap metrics identify unreliable MTV estimates using 1,014 autoPET FDG PET/CT studies. We evaluated LesionTracer predictions held out from fine-tuning, compared five selected released models on 489 tumor-positive patients, and examined the findings in 597 PSMA studies. Across the five FDG models, ranking by higher mean Dice gave the same order as ranking by lower mean relative MTV error ($\rho=-1.00$, exact $p=0.017$). At the patient level, however, out-of-fold Dice tracked relative MTV error strongly ($\rho=-0.75$), yet 82 of 489 patients (16.8\%) fell on opposite sides of the Dice 0.80 and MTV-error 25\% thresholds. Within the training-exposed released models, correlations ranged from $-0.47$ to $-0.74$ over narrower, high-Dice ranges. Out of fold, opposing false-positive and false-negative volumes cancelled about one third of spatial error in net MTV. In 236 of 489 patients, each of the five models missed at least one lesion, though not necessarily the same lesion. Thus, agreement in average model rankings did not establish the reliability of individual MTV estimates or reveal shared lesion misses. PET segmentation benchmarks should report patient-level MTV error and missed-lesion counts alongside Dice and other overlap metrics.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2611.05564 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-05T18:19:49.035Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).