Metraipolis › archive › dc_c1a43561caae
Actuator-Aware Observer Inputs for Cascade ADRC of Quadrotors Under Rotor Lag, Measurement Delay and Sensor Noise — arXiv:2610.39126
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.39126
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T02:44:21.642Z
- SHA-256 of the archived text
403738e82b4267cac3057db327fd168bceb13eb28b87dfa5bee97225a38fda79- Stable URL of this page
https://metraipolis.com/documento/dc_c1a43561caae
How to cite
Actuator-Aware Observer Inputs for Cascade ADRC of Quadrotors Under Rotor Lag, Measurement Delay and Sensor Noise — arXiv:2610.39126 — arXiv (en), https://arxiv.org/abs/2610.39126 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c1a43561caae (Metraipolis archive dc_c1a43561caae, sha256 403738e82b4267cac3057db327fd168bceb13eb28b87dfa5bee97225a38fda79)
BibTeX
@misc{dcc1a43561caae,
title = {Actuator-Aware Observer Inputs for Cascade ADRC of Quadrotors Under Rotor Lag, Measurement Delay and Sensor Noise — arXiv:2610.39126},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.39126},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c1a43561caae; sha256 403738e82b4267cac3057db327fd168bceb13eb28b87dfa5bee97225a38fda79},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39126. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
In sampled cascade linear active disturbance rejection control (LADRC) of quadrotors, the extended-state observer typically receives the instantaneous command, although the delayed measurement reflects an earlier, rotor-filtered acceleration. This paper proposes actuator-aware (AA) observer inputs: altitude and attitude observers use limited virtual inputs filtered by an assumed rotor model and aligned with the measurement delay, and horizontal observers use acceleration reconstructed from measured attitude. Fixed gains are selected on the discrete-time model under sensitivity and step-response requirements and stationary covariance ceilings on each channel's control variance and increment and on the noise-induced inner-loop increment of the full cascade. In paired set-point trials, PID-Budget, AA-Budget and AA-HalfGain reach mean RMSEs of 65.5, 19.2 and 16.9~mm; under a stricter common cascade ceiling, the AA designs reach 29.9 and 26.4~mm versus 72.3~mm for a PID that uses roughly double their rotor-command increment. PX4 software-in-the-loop runs reproduce these results. Behind EKF2, a noise model fitted to the estimation errors predicts the roll/pitch and yaw increments within 5\% on held-out and out-of-sample runs and the total rotor-command increment within 14\%. Redesigned for this stack under the same sensitivity and response specification and estimator-aware ceilings, AA-Budget-E reduces the set-point RMSE from 59.1~mm (PID-E) to 44.0~mm with a lower rotor-command increment in every paired set-point and lemniscate run (mean S6 rotor-command-increment reductions relative to PID-E: 45\% before and 15\% after output quantization); AA-HalfGain-E beats PID-E only on the lemniscate. The evidence is simulation-based, and the ceilings are nominal tuning constraints. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2610.39126 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:16:58.649Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).