Metraipolis › archive › dc_c1157392e40c
Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022 — Europe PMC PMID:39804917
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/39804917
- DOI
- 10.1371/journal.pone.0313319
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-06T13:46:55.683Z
- SHA-256 of the archived text
0b1d7c20696e5cc574e7cf809bbb89e62964808afd1c53dff77d30717b4e0a3f- Stable URL of this page
https://metraipolis.com/documento/dc_c1157392e40c
How to cite
Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022 — Europe PMC PMID:39804917 — Europe PMC (en), https://europepmc.org/article/MED/39804917 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_c1157392e40c (Metraipolis archive dc_c1157392e40c, sha256 0b1d7c20696e5cc574e7cf809bbb89e62964808afd1c53dff77d30717b4e0a3f)
BibTeX
@misc{dcc1157392e40c,
title = {Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022 — Europe PMC PMID:39804917},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/39804917},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_c1157392e40c; sha256 0b1d7c20696e5cc574e7cf809bbb89e62964808afd1c53dff77d30717b4e0a3f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/39804917. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Annual surveys of refugees in Gambella, Ethiopia suggest that anemia is a persistent public health problem among non-pregnant women of reproductive age (NP-WRA, 15-49 years). Measurement of anemia in most refugee camp settings is conducted using an invasive HemoCue 301. We assessed the accuracy and precision of a non-invasive, pulse CO-oximeter in measuring anemia among NP-WRA in four Gambella refugee camps. We conducted a population-representative household survey between November 7 and December 4, 2022. Hemoglobin (Hb) concentration was measured by HemoCue 301, using capillary blood, and Rad-67, a novel non-invasive device. We collected four measurements per participant: two per device. We calculated Rad-67 bias and precision of Hb measurements and sensitivity and specificity of detecting anemia. Of the 812 NP-WRAs selected, 807 (99%) participated in the study. Anemia was detected in 39% of NP-WRA as classified by the Rad-67 compared with 47% of NP-WRA as classified by the HemoCue 301. Average bias of Rad-67 measurements was 1.1 ± 1.0 SD g/dL, using HemoCue 301 as a comparator. Absolute mean difference between the first and second measurements was 0.9 g/dL (95% CI 0.8, 0.9) using the Rad-67, compared with 0.6 g/dL (95% CI 0.5, 0.6) using the HemoCue 301. The Rad-67 had 49% sensitivity and 70% specificity for detecting anemia, compared with the HemoCue 301. The Rad-67 can be a useful tool for anemia screening; however, lower accuracy and precision, and poor sensitivity suggest it cannot immediately replace the HemoCue 301 in the study area. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2025 (prima pubblicazione 2025-01-13). Identificativi: PMID 39804917 · PMCID PMC11729968 · DOI 10.1371/journal.pone.0313319. Descrittori MeSH principali: Anemia; Point-of-Care Systems. Pagina: https://europepmc.org/article/MED/39804917 — https://doi.org/10.1371/journal.pone.0313319. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-10-06T12:00:49.574Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.