Metraipolis › archive › dc_bfd73a2992d0
Photon-Counting Readout via Electro-Optic Microwave-to-Optical Transduction for Axion Haloscopes — arXiv:2611.05444
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.05444
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-05T18:33:06.541Z
- SHA-256 of the archived text
f08062499ee901270e7dbe82a93d5944588342bd86860d0f83181954b9d2e076- Stable URL of this page
https://metraipolis.com/documento/dc_bfd73a2992d0
How to cite
Photon-Counting Readout via Electro-Optic Microwave-to-Optical Transduction for Axion Haloscopes — arXiv:2611.05444 — arXiv (en), https://arxiv.org/abs/2611.05444 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bfd73a2992d0 (Metraipolis archive dc_bfd73a2992d0, sha256 f08062499ee901270e7dbe82a93d5944588342bd86860d0f83181954b9d2e076)
BibTeX
@misc{dcbfd73a2992d0,
title = {Photon-Counting Readout via Electro-Optic Microwave-to-Optical Transduction for Axion Haloscopes — arXiv:2611.05444},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.05444},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bfd73a2992d0; sha256 f08062499ee901270e7dbe82a93d5944588342bd86860d0f83181954b9d2e076},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05444. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Axion dark matter searches require highly sensitive detection schemes with high scan rate to efficiently explore the parameter space. Building upon the conventional Sikivie haloscope, where axions convert into microwave photons inside a magnetic-field-immersed resonant cavity, we present a photon-counting scheme based on an electro-optic microwave-to-optical transducer. Through a comprehensive theoretical model under realistic experimental constraints, we find that the optimal operating regime employs an overcoupled microwave cavity, trading peak transduction efficiency for reduced transducer noise. Furthermore, combining parameters already demonstrated in existing devices, in a device with optimized extrinsic coupling rates, would yield a scan-rate enhancement of 5-10 relative to quantum-limited homodyne detection. Improvements in quality factors, coupling rates, and thermal management push this enhancement beyond 50. While our quantitative model is benchmarked at 9 GHz, the scheme adapts well to haloscopes across the 5-12 GHz range, where shrinking cavity volumes severely degrade the achievable scan rate. These results demonstrate the potential of electro-optical photon detection as a high-speed detection technique for axion dark matter searches. Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno). Categorie arXiv: High Energy Physics - Phenomenology (hep-ph) ; High Energy Physics - Experiment (hep-ex); Quantum Physics (quant-ph). Pagina del lavoro: https://arxiv.org/abs/2611.05444 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-05T18:22:49.029Z dalla pagina https://arxiv.org/list/quant-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).