Metraipolis › archive › dc_bfb30692d670

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery — arXiv:2610.10346

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.10346
License (as archived)
CC0-1.0
Archived
2026-10-08T12:49:23.424Z
SHA-256 of the archived text
ae259870022262a2df5d25d6a3427e2b918b859115b055b47fbd85230c6e6470
Stable URL of this page
https://metraipolis.com/documento/dc_bfb30692d670

How to cite

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery — arXiv:2610.10346 — arXiv (en), https://arxiv.org/abs/2610.10346 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_bfb30692d670 (Metraipolis archive dc_bfb30692d670, sha256 ae259870022262a2df5d25d6a3427e2b918b859115b055b47fbd85230c6e6470)
BibTeX
@misc{dcbfb30692d670,
  title = {Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery — arXiv:2610.10346},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.10346},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_bfb30692d670; sha256 ae259870022262a2df5d25d6a3427e2b918b859115b055b47fbd85230c6e6470},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.10346. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2610.10346 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:18:30.577Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).